Double common bile duct - A rare case report and review of literature.

Doan Tu Trong, Pham Duong The, Van Nguyen Cuong, Tran Thanh Tuan, Van Nguyen Hai

Клинический случайСтатьяПеревод в очереди

Аннотация

INTRODUCTION

Extrahepatic bile duct duplication is an extremely rare congenital anomaly. There are five different types of this malformation. Due to unusual anatomy, the bile duct can be damaged during surgery. We herein report a case of double common bile duct and review the literature about this uncommon anatomical variation.

CASE PRESENTATION: A 72-year-old female was diagnosed with hepatic flexure colon cancer cT4bN1M0. The tumor invaded the pancreatic head and D2 duodenum in abdomen CT-scan. She underwent an en-bloc extended right hemicolectomy with duodenopancreatectomy and lymph node dissection. During surgery, we discovered that the cystic duct did not open into the common bile duct and there two parallel extrahepatic bile ducts merging into a single duct before draining into the D2 duodenum.

DISCUSSION: Bile duct duplication is an extremely rare congenital variation and has only been reported in the literature as clinical cases. According to Choi, there were five types of these anomalies, our clinical case was classified as type V of this classification.

CONCLUSION

We presented a case of double common bile duct discovered incidentally during surgery. The surgeons need to carefully expose the extrahepatic biliary tract to avoid bile duct injury.

Для цитирования: Doan Tu Trong, Pham Duong The, Van Nguyen Cuong, Tran Thanh Tuan, Van Nguyen Hai. Double common bile duct - A rare case report and review of literature.. International journal of surgery case reports. 2025. DOI: 10.1016/j.ijscr.2025.111519.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.