MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-2000-4646

Медицинская библиотека · RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin · 2000

[Diagnosis of pre-occlusive stenosis of the internal carotid artery by power mode ultrasound].

Jung E M, Butter F, Rupp N

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the accuracy of power mode (PM) vascular ultrasound in preocclusive (> 90%) stenosis of the extracranial internal carotid artery (ICA) compared to other diagnostic methods and to operative findings.

MATERIAL AND

METHODS

50 patients with preocclusive stenosis have been examined in a prospective study by power mode and color flow duplex ultrasound, by triplane aortic arch and four plane selective DSA. In 11 cases a MR angiography (time-of-flight) was available. Diagnostic findings were compared to operative results.

RESULTS

There was an agreement in findings in 50/50 patients (100%) for selective DSA, in 47/50 (94%) for power mode ultrasound, in 38/50 (76%) for aortic arch DSA, in 31/50 (62%) for color flow duplex ultrasound, and in 5/11 for MR angiography. In contrast to all other methods, ultrasound showed best the true extent of non-calcified atheromatous plaques. In extended vascular calcifications or kinking, however, only parts of the lumen of the vessel could be demonstrated.

CONCLUSION

Power mode ultrasound shows preocclusive stenosis of the ICA in a faster and more simple way than color flow duplex ultrasound and has diagnostic results near to those of selective DSA. It improves preoperative diagnostic screening.

Для цитирования: Jung E M, Butter F, Rupp N. [Diagnosis of pre-occlusive stenosis of the internal carotid artery by power mode ultrasound].. RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. 2000. DOI: 10.1055/s-2000-4646.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.