MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Neurosurgery · 2000

Parent vessel Guglielmi detachable coil herniation during wide-necked aneurysm embolization: treatment with intracranial stent placement: two technical case reports.

Lavine S D, Larsen D W, Giannotta S L, Teitelbaum G P

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE AND

IMPORTANCE

Despite recent advances in technology, parent vessel coil herniation occasionally complicates successful Guglielmi detachable coil embolization, particularly in wide-necked aneurysms. We report endovascular stent deployment performed in two patients specifically to treat this complication.

CLINICAL PRESENTATION: Two patients underwent Guglielmi detachable coil embolization of cavernous segment aneurysms. Both developed coil herniation into the internal carotid artery. In one patient, the herniation occurred during the initial procedure; in the other, it was discovered in a delayed fashion during a follow-up examination for ocular symptoms.

INTERVENTION: In both patients, endovascular stent deployment was performed to isolate the herniated portion of the coil from the internal carotid lumen. Follow-up angiography at 6 months demonstrated no aneurysm recanalization and no stenosis of the parent internal carotid artery in the stented region in either patient.

CONCLUSION

The use of intraluminal stents has been reported to be a helpful technical adjunct to the conventional endovascular treatment of aneurysms and balloon angioplasty. One additional indication for the use of this technology is sequestering herniated coils from the lumen of the parent artery to reduce potential embolic or occlusive sequelae.

Для цитирования: Lavine S D, Larsen D W, Giannotta S L, Teitelbaum G P. Parent vessel Guglielmi detachable coil herniation during wide-necked aneurysm embolization: treatment with intracranial stent placement: two technical case reports.. Neurosurgery. 2000.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.