Incidence of postoperative urinary retention (POUR) after joint arthroplasty and management using ultrasound-guided bladder catheterization.

Balderi T, Mistraletti G, D'Angelo E, Carli F

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Postoperative urinary retention (POUR) following lower limb arthroplasty is a common complication. The aim of this observational study was to establish the incidence of POUR and assess the usefulness of an ultrasonographic nurse-driven protocol, thereby avoiding elective bladder catheterization.

METHODS

Two-hundred and eighty six consecutive patients undergoing elective hip and knee arthroplasty were retrospectively studied. None of the patients received elective bladder catheterization. Data on risk factors for POUR, urinary tract infections, length of hospital stay and analgesia were collected. Student's t, Wilcoxon rank-sum, ANOVA and Kruskall-Wallis tests were performed for comparison among two or more groups. Categorical variables were studied using Pearson's χ2 test. Results were considered significant when the P value <0.05.

RESULTS

Of the 286 patients studied, 49 (17%) required indwelling catheter for 24-48 h. Patients who had POUR had more risk factors (P<0.05) and had longer hospital stays (P<0.05). When comparing analgesia, continuous peripheral nerve block (CPNB) had the least impact on POUR (15.8%), while epidural analgesia had the greatest impact (48.1%).

CONCLUSION

Bladder scanners timely detect POUR following lower joint arthroplasty, making elective bladder catheterization unnecessary.

Для цитирования: Balderi T, Mistraletti G, D'Angelo E, Carli F. Incidence of postoperative urinary retention (POUR) after joint arthroplasty and management using ultrasound-guided bladder catheterization.. Minerva anestesiologica. 2011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.