Comparison of peak versus onset latency measurements in electrodiagnostic tests for carpal tunnel syndrome.

Kasius Kristel M, Claes Franka, Meulstee Jan, Weinstein Henry C, Verhagen Wim I M

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The aim of this prospectively conducted study was to compare the diagnostic accuracy of onset versus peak latency measurements of sensory nerve action potentials in electrodiagnostic studies in diagnosing carpal tunnel syndrome.

METHODS

In 156 consecutive patients with clinically defined carpal tunnel syndrome, standardized nerve conduction studies (DIG1, DIG4, PALM3) were performed. Both onset and peak latency were measured. Sensitivity was calculated using the clinical diagnosis as golden standard. Bland-Altman plots were constructed to assess the agreement for quantitative measurements. Overall agreement, positive and negative percent agreement, and Kappa coefficient were computed.

RESULTS

The Bland-Altman plots, positive and negative percent agreement show good overall agreement. The kappa coefficient was 0.850, 0.847, and 0.815 for DIG1, DIG4, and PALM3, respectively.

CONCLUSIONS

Onset and peak latencies used in electrodiagnostic tests show a good overall agreement in confirming the clinical diagnosis of carpal tunnel syndrome. Because onset latency measurement represents nerve conduction velocity of the fastest conducting fibers, the use of onset latencies is recommend. In case of uncontrollable stimulus artifacts, peak latencies may be used instead.

Для цитирования: Kasius Kristel M, Claes Franka, Meulstee Jan, Weinstein Henry C, Verhagen Wim I M. Comparison of peak versus onset latency measurements in electrodiagnostic tests for carpal tunnel syndrome.. Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society. 2014. DOI: 10.1097/wnp.0000000000000069.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.