m+Medelevator.RU
← Поиск публикаций
Ophthalmic plastic and reconstructive surgery · 2023

Ten-Year Follow-Up of Orbital Volume Augmentation With Calcium Hydroxyapatite Filler in Postenucleation Socket Syndrome.

Наблюдательное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Di Maria Alessandra, Ferraro Vanessa, Trenti Nicoletta, Morenghi Emanuela, Gaeta Alessandro, Vinciguerra Paolo, Confalonieri Filippo

Аннотация

PURPOSE: To describe the efficacy and persistence of injectable calcium hydroxyapatite (CAHY) to correct orbital volume deficit in postenucleation socket syndrome.

METHODS: An observational study was conducted as a clinical review of all patients in the authors' practice who received injectable CAHY placed in the extraconal and intraconal space to increase orbital volume with a 10-year follow up. The amount of CAHY to be injected was defined according to the degree of orbital volume deficit. Patients previously treated with radiotherapy or with a conjunctival fornix insufficient to accommodate the external prosthesis were excluded. All the patients with at least 10 years of follow up were included in the study.

RESULTS: Thirty-one postenucleation socket syndrome patients received injectable CAHY for orbital volume augmentation, with a 10-year follow up. The mean amount of preoperative relative enophthalmos measured by Hertel's exophthalmometry was 14.16 ± 2.15. An increase in the mean orbital volume of 3.35 ± 0.91 at 6 months and 2.97 ± 1.35 at 10 years was obtained. The mean follow-up was 219 ± 18 months (range, 184-240). Patients demonstrated clinical and cosmetic improvement that was observed to continue for 10 years. The complications were peribulbar ecchymosis, 2 extrusions of the internal prosthesis, and 2 ptosis.

CONCLUSIONS: Injectable CAHY provides safe, simple, repeatable, and cost-effective technique to treat volume deficiency in the enophthalmic orbit in the long term. The volume augmentation obtained with this semipermanent filler demonstrated a lasting effect in the orbit with negligible loss of volume at 10 years.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049