MedElevator Войти в исследования
← Поиск публикаций

DOI 10.23736/s0393-2249.18.03143-0

Медицинская библиотека · Minerva urologica e nefrologica = The Italian journal of urology and nephrology · 2018

Augmented reality during robot-assisted radical prostatectomy: expert robotic surgeons' on-the-spot insights after live surgery.

Porpiglia Francesco, Bertolo Riccardo, Amparore Daniele, Checcucci Enrico, Artibani Walter, Dasgupta Prokar, Montorsi Francesco, Tewari Ashutosh, Fiori Cristian, ESUT

СтатьяПеревод пока не подготовлен

Аннотация

3D reconstruction of the standard two-dimension cross-sectional imaging has known increasing diffusion. It may represent one of the key points for a tailored treatment planning. Along these lines, we used a novel software for augmented-reality robot-assisted radical prostatectomy (AR-RARP) at our Institution. 3D virtual models of the prostate and the prostate cancer were reconstructed from high resolution (1-mm slices) multi-parametric Magnetic Resonance Imaging (mp-MRI) by M3dics (Turin, Italy). The innovation in the study is represented by the software-based integration of the virtual model inside the Da Vinci (Intuitive, Sunnyvale, CA, USA) robotic console during robotic prostatectomy. In January 2018, the above-described AR-RARP technique has been used during the live surgery sessions of the 6th Techno-Urology Meeting held at San Luigi Gonzaga Hospital (Orbassano, Turin, Italy). During this meeting, 6 experienced robotic surgeons (who have already performed more than 1000 RARP) used the software during nerve-sparing prostatectomy. The use of the technology was standardized to four key steps during the procedure: 1) bladder neck dissection; 2) nerve-sparing technique; 3) apex dissection; and 4) tailoring of eventual selective biopsies of prostatic lodge after prostatectomy). A Face Validity questionnaire was purpose-built aimed to collect the expert surgeons' insights about the eventual help of the technology in guiding the surgeon during the above-described AR-RARP steps. It was administered at the end of the surgeries to the respective surgeons. The questionnaire was made of open-ended questions of ordinal ten-point rating Likert Scale (where 1 corresponded to a strongly negative opinion and 10 to a strongly positive opinion). The median value of Likert scale from the evaluation of each of the aforementioned steps of AR-RARP was 9, (IQR 9-10). These findings are a confirmation of the increasing interest for a new-generation of image-guided surgery. Particularly, AR-RARP seems to be a step in the direction of "precision" surgery.

Для цитирования: Porpiglia Francesco, Bertolo Riccardo, Amparore Daniele, Checcucci Enrico, Artibani Walter, Dasgupta Prokar, Montorsi Francesco, Tewari Ashutosh, Fiori Cristian, ESUT. Augmented reality during robot-assisted radical prostatectomy: expert robotic surgeons' on-the-spot insights after live surgery.. Minerva urologica e nefrologica = The Italian journal of urology and nephrology. 2018. DOI: 10.23736/s0393-2249.18.03143-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.