MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/diagnostics12123008

Медицинская библиотека · Diagnostics (Basel, Switzerland) · 2022

Novel Decision Tool for More Severe α-Thalassemia Genotypes Screening with Functional Loss of Two or More α-Globin Genes: A Diagnostic Test Study.

Siqueira Patricia F R, Fleury Marcos K, Pontes Robéria M, Silva Renata S P, Costa Elaine S, Land Marcelo G P

СтатьяПеревод пока не подготовлен

Аннотация

After the exclusion of iron deficiency and β-thalassemia, molecular research for α-thalassemia is recommended to investigate microcytic anemia. Aiming to suggest more efficiently the molecular analysis for individuals with a greater chance of having a symptomatic form of the disease, we have developed and validated a new decision tool to predict the presence of two or more deletions of α-thalassemia, increasing considerably the pre-test probability. The model was created using the variables: the percentage of HbA2, serum ferritin and mean corpuscular volume standardized by age. The model was trained in 134 patients and validated in 160 randomly selected patients from the total sample. We used Youden's index applied to the ROC curve methodology to establish the optimal odds ratio (OR) cut-off for the presence of two or more α-globin gene deletions. Using the OR cut-off of 0.4, the model's negative predictive value (NPV) was 96.8%; the cut-off point accuracy was 85.4%; and the molecular analysis pre-test probability increased from 25.9% to 65.4% after the use of the proposed model. This tool aims to assist the physician in deciding when to perform molecular studies for the diagnosis of α-thalassemia. The model is useful in places with few financial health resources.

Для цитирования: Siqueira Patricia F R, Fleury Marcos K, Pontes Robéria M, Silva Renata S P, Costa Elaine S, Land Marcelo G P. Novel Decision Tool for More Severe α-Thalassemia Genotypes Screening with Functional Loss of Two or More α-Globin Genes: A Diagnostic Test Study.. Diagnostics (Basel, Switzerland). 2022. DOI: 10.3390/diagnostics12123008.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.