MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cardfail.2022.10.423

Медицинская библиотека · Journal of cardiac failure · 2022

Minimal Clinically Important Differences in 6-Minute Walk Test in Patients With HFrEF and Iron Deficiency.

Khan Muhammad Shahzeb, Anker Stefan D, Friede Tim, Jankowska Ewa A, Metra Marco, Piña Ileana L, Coats Andrew Js, Rosano Giuseppe, Roubert Bernard, Goehring Udo-Michael, Dorigotti Fabio, Comin-Colet Josep, Vanveldhuisen Dirk J, Filippatos Gerasimos S, Ponikowski Piotr, Butler Javed

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The 6-minute walk test (6MWT) is widely used to measure exercise capacity; however, the magnitude of change that is clinically meaningful for individuals is not well established in heart failure with reduced ejection fraction (HFrEF).

OBJECTIVE

To calculate the minimal clinically important difference (MCID) for change in exercise capacity in the 6MWT in iron-deficient populations with HFrEF.

METHODS

In this pooled secondary analysis of the FAIR-HF and CONFIRM-HF trials, mean changes in the 6MWT from baseline to weeks 12 and 24 were calculated and calibrated against the Patient Global Assessment (PGA) tool (clinical anchor) to derive MCIDs in improvement and deterioration.

RESULTS

Of 760 patients included in the 2 trials, 6MWT and PGA data were available for 680 (89%) and 656 (86%) patients at weeks 12 and 24, respectively. The mean 6MWT distance at baseline was 281 ± 103 meters. There was a modest correlation between changes in 6MWT and PGA from baseline to week 12 (r = 0.31; P < 0.0001) and week 24 (r = 0.43; P < 0.0001). Respective estimates (95% confidence intervals) of MCID in 6MWT at weeks 12 and 24 were 14 meters (5;23) and 15 meters (3;27) for a "little improvement" (vs no change), 20 meters (10;30) and 24 meters (12;36) for moderate improvement vs a "little improvement,", -11 meters (-32;9.2) and -31 meters (-53;-8) for a "little deterioration" (vs no change), and -84 meters (-144;-24) and -69 meters (-118;-20) for "moderate deterioration" vs a "little deterioration".

CONCLUSIONS

The MCID for improvement in exercise capacity in the 6MWT was 14 meters-15 meters in patients with HFrEF and iron deficiency. These MCIDs can aid clinical interpretation of study data.

Для цитирования: Khan Muhammad Shahzeb, Anker Stefan D, Friede Tim, Jankowska Ewa A, Metra Marco, Piña Ileana L, Coats Andrew Js, Rosano Giuseppe, Roubert Bernard, Goehring Udo-Michael, Dorigotti Fabio, Comin-Colet Josep, Vanveldhuisen Dirk J, Filippatos Gerasimos S, Ponikowski Piotr, Butler Javed. Minimal Clinically Important Differences in 6-Minute Walk Test in Patients With HFrEF and Iron Deficiency.. Journal of cardiac failure. 2022. DOI: 10.1016/j.cardfail.2022.10.423.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.