m+Medelevator.RU
← Поиск публикаций
Journal of cardiothoracic and vascular anesthesia · 2020

A Pharmacokinetic and Pharmacodynamic Investigation of an ε-Aminocaproic Acid Regimen Designed for Cardiac Surgery With Cardiopulmonary Bypass.

СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Strauss Erik R, Dahmane Elyes, Judd Miranda, Guo Dong, Williams Brittney, Meyer Michael, Gammie James S, Taylor Bradley, Mazzeffi Michael A, Gobburu Jogarao V S, Tanaka Kenichi A

Аннотация

OBJECTIVE: To investigate the pharmacokinetics and pharmacodynamics of an ε-aminocaproic acid (EACA) regimen designed for cardiac surgery with cardiopulmonary bypass (CPB).

DESIGN: Prospective observational study requiring blood sampling to measure EACA concentrations and fibrinolysis markers (fibrinogen, D-dimer, α2-antiplasmin, and tissue plasminogen activator-plasminogen activator inhibitor [tPA-PAI-1] complex).

SETTING: Single-center, tertiary medical center.

PARTICIPANTS: Patients who underwent cardiac surgery with CPB between 2018 and 2019 for aortic or mitral valve replacement/repair or coronary artery bypass grafting. Previous sternotomy patients were included.

INTERVENTION: None.

MEASUREMENTS AND MAIN RESULTS: The pharmacokinetics of EACA, during CPB, were described by a 3-compartment disposition model. EACA concentrations were greater than 130 mg/L in all patients after CPB and in most patients during CPB. The D-dimer level trended up and reached a peak median level of 1.35 mg/L of fibrinogen equivalence units (FEU) at 15 minutes after protamine administration. The median change in D-dimer (ΔD-dimer) from baseline to 15 minutes after protamine was 0.34 (-0.48 to 3.81) mg/L FEU. ΔD-dimer did not correlate with EACA concentration intraoperatively, urine output, body weight, glomerular filtration rate, cell salvage volume, and ultrafiltration volume. The median 24-hour chest tube output was 445 (180-1,011) mL.

CONCLUSION: This regimen provided maximum EACA concentrations near the time of protamine administration, with a total perioperative dose of 15 g. Most patients had EACA concentrations greater than the target during CPB. ΔD-dimer did not correlate with EACA concentration. The median 24-hour chest tube output compared well to similar studies that used higher doses of EACA.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты