MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00380-019-01368-3

Медицинская библиотека · Heart and vessels · 2019

Randomized comparison between 2-link cell design biolimus A9-eluting stent and 3-link cell design everolimus-eluting stent in patients with de novo true coronary bifurcation lesions: the BEGIN trial.

Yamawaki Masahiro, Muramatsu Toshiya, Ashida Kazuhiro, Kishi Koichi, Morino Yoshihiro, Kinoshita Yoshihisa, Fujii Takashi, Noguchi Yuichi, Hosogi Shingo, Kawai Kazuya, Hibi Kiyoshi, Shibata Yoshisato, Ohira Hiroshi, Morita Yasuhiro, Tarutani Yasuhiro, Toda Mikihito, Shimada Yoshihisa, Ikari Yuji, Ando Jiro, Hikichi Yutaka, Otsuka Yoritaka, Fuku Yasushi, Ito Shigenori, Katoh Harumi, Kadota Kazushige, Ito Yoshiaki, Mitsudo Kazuaki

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

The appropriate stent platform for treating coronary bifurcation lesions (CBLs) remains controversial. Previous bench tests have demonstrated the superiority of a 2-link cell design to 3-link cell design for creating inter-strut dilation at the side branch ostium. This randomized multicenter prospective BEGIN trial compared the biodegradable polymer-based biolimus A9-eluting stent (2-link BES) with the durable polymer-based cobalt chromium everolimus-eluting stent (3-link EES) in 226 patients with de novo CBLs. Patients with true bifurcations, defined as > 50% stenosis in the main vessel and side branch (SB) and an SB diameter > 2.25 mm, were enrolled. Guide wire re-crossing to the distal cell (near the carina) in the jailed SB and final kissing inflation were recommended. The SB angiographic endpoint was < 50% stenosis diameter. Left-main CBLs (13.5% vs. 13.0%) and 2-stent technique (30.6% vs. 22.6%) rates were similar. The primary endpoints (minimum lumen diameter at the SB ostium measured at an independent core laboratory at the 8-month follow-up) were comparable (1.64 ± 0.50 mm vs. 1.63 ± 0.51 mm, p = 0.976). There was no significant difference in composite outcomes of cardiac death, myocardial infarction, or target vascular revascularization at 12 months (7.4% vs. 8.0%, p = 0.894). Two-link BES and 3-link EES showed similar 8-month angiographic and 1-year clinical outcomes for true CBLs.

Для цитирования: Yamawaki Masahiro, Muramatsu Toshiya, Ashida Kazuhiro, Kishi Koichi, Morino Yoshihiro, Kinoshita Yoshihisa, Fujii Takashi, Noguchi Yuichi, Hosogi Shingo, Kawai Kazuya, Hibi Kiyoshi, Shibata Yoshisato, Ohira Hiroshi, Morita Yasuhiro, Tarutani Yasuhiro, Toda Mikihito, Shimada Yoshihisa, Ikari Yuji, Ando Jiro, Hikichi Yutaka, Otsuka Yoritaka, Fuku Yasushi, Ito Shigenori, Katoh Harumi, Kadota Kazushige, Ito Yoshiaki, Mitsudo Kazuaki. Randomized comparison between 2-link cell design biolimus A9-eluting stent and 3-link cell design everolimus-eluting stent in patients with de novo true coronary bifurcation lesions: the BEGIN trial.. Heart and vessels. 2019. DOI: 10.1007/s00380-019-01368-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.