Incidence and Clinical Impact of Device-Related Thrombus Following Percutaneous Left Atrial Appendage Occlusion: A Meta-Analysis.

Alkhouli Mohamad, Busu Tatiana, Shah Kuldeep, Osman Mohammed, Alqahtani Fahad, Raybuck Bryan

СтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study sought to assess the incidence and clinical impact of device related thrombus (DRT) following precautions left atrial appendage occlusion (LAAO).

BACKGROUND

Device-related thrombus is a known complication of LAAO. However, data on the incidence of DRT and its impact on outcomes are limited.

METHODS

The authors performed a meta-analysis of randomized and observational studies to calculate the pooled incidence of DRT and the pooled odds ratio (OR) of ischemic events in patients with DRT and those without DRT.

RESULTS

In the 66 included studies; the incidence of DRT was 351/10, 153 (3.8%, range 0% to 17%, I2 = 56.8). The diagnosis was made in <90, 90 to 365, and >365 days in 42%, 57%, and 1% of patients, respectively. There was no difference in DRT rates between the AMPLATZER (AMPLATZER, AGA Medical Corporation, Golden Valley, Minnesota) and WATCHMAN (WATCHMAN, Boston Scientific Corporation, Marlborough, Massachusetts) devices (3.6% vs. 3.1%, p = 0.24). In a meta-regression, age, gender, heart failure, diabetes, CHA2DS2-VASc score, previous stroke, and post-LAAO antithrombotic regimen did not explain the heterogeneity in the incidence of DRT. The pooled incidence of ischemic events in studies that compared outcomes of patients with and without DRT (32 studies; n = 7,689) was 13.2% (37 of 280) in patients with DRT and 3.8% (285 of 7,399) in those without DRT (OR: 5.27, 95% confidence interval [CI]: 3.66 to 7.59; p < 0.001, I2 = 0). In a sensitivity analysis including randomized trials and prospective multicenter registries, the incidence of DRT was 3.7%, and DRT remained associated with higher rates of ischemic events (13.5% vs. 4.4%, OR: 4.15, 95% CI: 2.77 to 6.22; p < 0.001, I2 = 0).

CONCLUSIONS

DRT after LAAO is uncommon (3.8%) but is associated with a 4- to 5-fold increase in ischemic events. Further studies are needed to understand the underlying mechanisms and the optimal surveillance and management of DRT.

Для цитирования: Alkhouli Mohamad, Busu Tatiana, Shah Kuldeep, Osman Mohammed, Alqahtani Fahad, Raybuck Bryan. Incidence and Clinical Impact of Device-Related Thrombus Following Percutaneous Left Atrial Appendage Occlusion: A Meta-Analysis.. JACC. Clinical electrophysiology. 2018. DOI: 10.1016/j.jacep.2018.09.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.