MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/eus.0000000000000086

Медицинская библиотека · Endoscopic ultrasound · 2024

Safety of the contrast enhancement agent sulfur hexafluoride in ultrasound: Analysis of the Federal Drug Administration Adverse Event Reporting System database.

Walker Courtney N, Andrews Michael B, Adler Douglas G

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVES

Sulfur hexafluoride is an inert gas that creates microbubbles to enhance diagnostic accuracy in a variety of ultrasound (US) studies and is widely used in EUS. We analyzed the reported adverse events (AEs) of the US contrast agent, sulfur hexafluoride, extensively used during EUS procedures using a US national database.

METHODS

From December 2008 to January 2024, AEs reported in the Federal Drug Administration Adverse Event Reporting System database for sulfur hexafluoride were examined.

RESULTS

There were 1069 individual reports analyzed. Reports were excluded if they contained drugs other than sulfur hexafluoride. Echocardiogram (70.9%) was the common diagnostic study in which sulfur hexafluoride was administered. The most common AE reported was anaphylactic reaction (n = 179, 16.7%), followed by hypotension (n = 162, 15.2%), cardiac arrest (n = 161, 15.1%), and dyspnea (n = 159, 14.9%). The most common gastrointestinal AE was nausea (n = 135, 12.6%). Severity of AEs ranged from nonserious to death. Death associated with sulfur hexafluoride use was reported in 58 patients (5.4% of AE reports).

CONCLUSIONS

Anaphylactic reaction was the most common AE reported with sulfur hexafluoride use, and severe AEs including death may be more common than prior large, retrospective, observational studies to date have suggested.

Для цитирования: Walker Courtney N, Andrews Michael B, Adler Douglas G. Safety of the contrast enhancement agent sulfur hexafluoride in ultrasound: Analysis of the Federal Drug Administration Adverse Event Reporting System database.. Endoscopic ultrasound. 2024. DOI: 10.1097/eus.0000000000000086.