Predictors of venous stenosis or occlusion following first transvenous cardiac device implantation: Prospective observational study.

Cacko Andrzej, Kozyra-Pydyś Eliza, Gawałko Monika, Opolski Grzegorz, Grabowski Marcin

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

INTRODUCTION

Venous stenosis or occlusion related to an intracardiac device is a well-known complication of that procedure. There are numerous studies tried to determine predictors of venous stenosis or occlusion; however, most of them investigate the venous system prior to device upgrade, generator replacement, or transvenous lead extraction. Therefore, we aimed to assess the prevalence and determine the predictors of venous stenosis or occlusion following first transevnous cardiac device implantation.

METHODS

Observational, prospective study included 71 consecutive patients admitted for first transvenous cardiac device implantation. All patients were followed up for 6 months after operation.

RESULTS

Implanted device systems comprised cardioverter defibrillator (n = 26), single-chamber or dual-chamber pacemakers (n = 34), and biventricular pacemakers (n = 11); 88.5% of implantable cardioverter defibrillator leads were single-coils and 11.5% were dual-coils. The incidence of venous stenosis or occlusion within 6-month follow-up was 21.1%. Multivariate logistic regression showed that only diabetes or prediabetes (p = 0.033, odds ratio: 0.17, 95% confidence interval: 0.04-0.87), prolonged procedure time (p = 0.046, odds ratio: 4.54, 95% confidence interval: 1.01-20.12), and perioperative complications (p = 0.021, odds ratio: 7.04, 95% confidence interval: 1.35-36.85) were predictors of venous stenosis or occlusion.

CONCLUSION

Prolonged implantation time (>60 min) and perioperative complications are associated with an increased risk of venous stenosis or occlusion, whereas diabetes and prediabetes significantly reduce the risk of venous stenosis or occlusion.

Для цитирования: Cacko Andrzej, Kozyra-Pydyś Eliza, Gawałko Monika, Opolski Grzegorz, Grabowski Marcin. Predictors of venous stenosis or occlusion following first transvenous cardiac device implantation: Prospective observational study.. The journal of vascular access. 2018. DOI: 10.1177/1129729818815135.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.