MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ijo.ijo_348_24

Медицинская библиотека · Indian journal of ophthalmology · 2024

Evaluation of change in the contact of IOL with the posterior capsule with respect to the orientation of haptics of the IOL using intraoperative spectral domain optical coherence tomography.

Shetty Naren, Patel Yash, Ranade Reshma, Jain Akash, Narasimhan Raghav, Bansod Apurva, Nuijts Rudy

СтатьяПеревод в очереди

Аннотация

PURPOSE: To study change in the contact of intraocular lens (IOL) with the posterior capsule with respect to the vertical versus horizontal orientation of the haptic-optic junction of the IOL using intraoperative spectral domain optical coherence tomography (SD-OCT).

METHODS

Fifty eyes of 50 patients with senile immature cataract underwent topical phacoemulsification procedure with implantation of a monofocal IOL by a single experienced surgeon. The Rescan 700 SD-OCT system was used for intraoperative imaging. These patients were imaged using intraoperative SD-OCT after implantation of IOL, with the haptics oriented horizontally and then vertically.

RESULTS

The vertical height between the posterior surface of the lens capsule and the posterior surface of IOL reduced significantly when the haptics were oriented vertically compared to horizontal orientation. This difference was found on analyzing both vertical as well as horizontal axis scans.

CONCLUSION

We found a greater contact between the posterior capsule and the posterior surface of IOL, with the haptic optic junction of the IOL oriented vertically. This study also suggests the need for newer toric IOL designs which allow vertical orientation of haptics, leading to better contact between IOL and the bag.

Для цитирования: Shetty Naren, Patel Yash, Ranade Reshma, Jain Akash, Narasimhan Raghav, Bansod Apurva, Nuijts Rudy. Evaluation of change in the contact of IOL with the posterior capsule with respect to the orientation of haptics of the IOL using intraoperative spectral domain optical coherence tomography.. Indian journal of ophthalmology. 2024. DOI: 10.4103/ijo.ijo_348_24.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.