Diode laser photoablation to correct distal nasolacrimal duct atresia in an adult horse.

Stoppini Riccardo, Tassan Stefano, Barachetti Laura

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

CASE DESCRIPTION: An 8-year-old Hanoverian mare was presented for chronic mucopurulent discharge in the left eye, which was responsive to topical antibiotic therapy.

CLINICAL FINDINGS: The nasolacrimal orifice was absent in the left nasal meatum, and anterograde irrigation of left nasolacrimal duct was not possible. Dacryocystorhinography was performed and revealed about 4-6 cm of distal nasolacrimal duct atresia.

SURGICAL TREATMENT AND OUTCOME: A novel technique was attempted with the horse under standing sedation using an urinary catheter and a 980 nm diode laser with a 600 μm diameter flexible bare quartz fiber. A nasolacrimal orifice was successfully created by ablating the nasal mucosa directly over the tip of the urinary catheter, and patency was maintained with a soft catheter sutured in place for 4 weeks. At 3 months re-evaluation, the left nasolacrimal duct was patent and functional.

CONCLUSION

This case report describes a successful novel surgical technique used to correct congenital distal nasolacrimal duct atresia in an adult horse under standing sedation. Advantages over conventional surgical techniques are shorter operating time and limited hemorrhage.

Для цитирования: Stoppini Riccardo, Tassan Stefano, Barachetti Laura. Diode laser photoablation to correct distal nasolacrimal duct atresia in an adult horse.. Veterinary ophthalmology. 2014. DOI: 10.1111/vop.12164.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.