MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5152/dir.2019.19259

Медицинская библиотека · Diagnostic and interventional radiology (Ankara, Turkey) · 2020

Prediction of degree of carotid stenosis with the transluminal attenuation difference ratio.

Gürsoy Çoruh Ayşegül, Peker Elif, Gülpınar Başak, Sorgun Mine Hayriye, Elhan Atilla Halil, Fitoz Ömer Suat

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: We aimed to assess the diagnostic performance of transluminal attenuation difference (TAD) in predicting the severity of internal carotid artery (ICA) stenosis.

METHODS

The study cohort consisted of 48 patients with <50% stenosis, 50%-69% stenosis, 70%-99% stenosis, and 51 controls without plaque development in ICA. A total of 143 measurements were performed through right and left internal and common carotid arteries. The TAD ratio was calculated as the difference between the mean attenuation values of the common carotid artery (CCA) and ICA, divided by the MAV of the CCA, multiplied by 100.

RESULTS

TAD ratio was significantly higher in severe (>70%) stenosis compared with control arteries and low-moderate stenosis. A TAD ratio cutoff of 4.5 predicted 70%-99% stenosis with a sensitivity of 100% and specificity of 93%. The inter- and intraobserver agreements in TAD measurements were almost perfect (ICC, 0.89-0.86).

CONCLUSION

Assessment of TAD ratio predicts the degree of stenosis in concordance with NASCET system.

Для цитирования: Gürsoy Çoruh Ayşegül, Peker Elif, Gülpınar Başak, Sorgun Mine Hayriye, Elhan Atilla Halil, Fitoz Ömer Suat. Prediction of degree of carotid stenosis with the transluminal attenuation difference ratio.. Diagnostic and interventional radiology (Ankara, Turkey). 2020. DOI: 10.5152/dir.2019.19259.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.