Movement of internal canalicular orifice in association with blinking: direct observation after dacryocystorhinostomy.
Аннотация
PURPOSE: To examine movement of the internal canalicular orifice with blinking and lacrimal drainage under endonasal endoscopic observation after dacryocystorhinostomy.
DESIGN
Observational anatomic study.
METHODS
Twenty internal canalicular orifices (right 9, left 11) from 15 patients (age range: 44-77 years) who underwent endoscopic endonasal dacryocystorhinostomy were prospectively examined. The patients sat on a chair with the chin projected slightly upward while digital images were taken. After examining the movement of the internal canalicular orifice with blinking, the patient's eye was stained with fluorescein dye, and diffusion from the orifice was examined with blinking.
RESULTS
The internal canalicular orifice closed during eyelid opening, although always incompletely. In eyelid closing, the orifice opened, and was pulled laterally without folds. All 20 internal canalicular orifices formed a diverticulum. Three specimens illustrated the upper and lower canalicular ends emptying into the diverticulum. The closing of these canalicular ends was always incomplete. Movement of the internal canalicular orifice was slight during normal blinking, but forced blinking resulted in more movement. Movement of the lacrimal sac wall was slight. During the first few seconds without blinking, no fluorescein dye flowed from the orifice. After several blinks, fluorescein dye flowed out slowly from the orifice, and increased in volume with more blinking. The fluorescein dye traveled inferiorly by gravity. A forced blinking was related to more dye inflow.
CONCLUSIONS
The internal canalicular orifice incompletely closed during eyelid opening, but this orifice largely opened during eyelid closing, with a slow gravitational inflow of lacrimal fluid.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.