MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcjo.2012.10.005

Медицинская библиотека · Canadian journal of ophthalmology. Journal canadien d'ophtalmologie · 2013

Voluntary blinking and use of 0.25% dye on fluorescein dye disappearance test.

Kim Cheol, Lee Min Joung, Khwarg Sang In

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the effect of voluntary blinking and use of diluted fluorescein dye on fluorescein dye disappearance test (FDDT) in terms of diagnostic ability and test time.

DESIGN

Prospective, nonrandomized case series.

PARTICIPANTS

Thirty-nine patients who visited Hadong Seoul Eye Clinic between April 2009 and September 2009.

METHODS

All participants underwent FDDT and a lacrimal syringing test, and were divided into 2 groups according to the lacrimal syringing test results. FDDT was performed using 3 protocols: conventional FDDT (2% FDDT), FDDT with voluntary blinking (2% FDDTb), and FDDT with voluntary blinking using diluted fluorescein (0.25% FDDTb). The results were assessed by comparing initial tear meniscus height and those at 5 (2% FDDT) or 3 minutes (2% FDDTb, 0.25% FDDTb) after dye instillation. Results were considered "normal" when the tear meniscus decreased to less than 50% of its initial height, and "delayed" when it decreased to≥50%. In cases with a normal result, a half-period of dye disappearance was also recorded.

RESULTS

Regarding diagnostic ability, the 0.25% FDDTb test had highest sensitivity and specificity among 3 protocols (100% and 80%, respectively). The half-period of dye disappearance was 3.17±1.72 minutes for 2% FDDT, 1.82±0.64 minutes for 2% FDDTb, and 1.04±0.69 minutes for 0.25% FDDTb, and showed significant difference among 3 tests (P = 0.001).

CONCLUSIONS

The FDDT with voluntary blinking using 0.25% fluorescein had comparable diagnostic ability with the conventional FDDT, and allowed the test time to be significantly reduced.

Для цитирования: Kim Cheol, Lee Min Joung, Khwarg Sang In. Voluntary blinking and use of 0.25% dye on fluorescein dye disappearance test.. Canadian journal of ophthalmology. Journal canadien d'ophtalmologie. 2013. DOI: 10.1016/j.jcjo.2012.10.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.