MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/hepr.14190

Медицинская библиотека · Hepatology research : the official journal of the Japan Society of Hepatology · 2025

Validation of a B-mode ultrasonography scoring system for assessing liver steatosis: A comparison with MRI-Derived proton density fat fraction.

Tada Toshifumi, Kumada Takashi, Gotoh Tatsuya, Niwa Fumihiko, Ogawa Sadanobu, Yasuda Satoshi, Koshiyama Yuichi, Akita Tomoyuki, Tanaka Junko, Kodama Yuzo, Toyoda Hidenori

СтатьяПеревод пока не подготовлен

Аннотация

AIM: Noninvasive detection of liver steatosis and monitoring its progression are essential for effective therapeutic management. We validated the diagnostic performance of an ultrasonography (US)-based steatotic liver scoring system, derived from the B-mode method and the hepatic steatosis index (HSI) for the detection of liver steatosis, as identified by proton density fat fraction (PDFF) measurements on magnetic resonance imaging (MRI).

METHODS

A total of 916 patients with chronic liver disease were included in the analysis.

RESULTS

The median MRI-PDFF value was 4.0% (interquartile range: 2.0-9.7). The distribution of scores (0/1/2/3/4/5/6) according to the US-based steatotic liver scoring system was as follows: 475, 36, 99, 78, 141, 66, and 21, respectively. The median HSI was 32.8 (28.9-37.4). A significant positive association between advancing scores of the US-based steatotic liver scoring system and increasing MRI-PDFF values was observed (p < 0.001). The diagnostic performance of the US-based steatotic liver scoring system and HSI for detecting steatosis grades ≥1, ≥2, and 3, as determined by MRI-PDFF, showed areas under the receiver operating characteristic curve of 0.940 and 0.842 (p < 0.001), 0.949 and 0.847 (p < 0.001), and 0.945 and 0.864 (p < 0.001), respectively. When the cutoff values of the scoring system were set at 2, 3, and 4 for steatosis grades ≥1, ≥2, and 3, the sensitivity and specificity were 90.6% and 90.5%, 92.9% and 83.0%, and 93.3% and 84.0%, respectively.

CONCLUSION

The B-mode US-based steatotic liver scoring system demonstrated robust diagnostic capability in detecting liver steatosis.

Для цитирования: Tada Toshifumi, Kumada Takashi, Gotoh Tatsuya, Niwa Fumihiko, Ogawa Sadanobu, Yasuda Satoshi, Koshiyama Yuichi, Akita Tomoyuki, Tanaka Junko, Kodama Yuzo, Toyoda Hidenori. Validation of a B-mode ultrasonography scoring system for assessing liver steatosis: A comparison with MRI-Derived proton density fat fraction.. Hepatology research : the official journal of the Japan Society of Hepatology. 2025. DOI: 10.1111/hepr.14190.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.