DOI 10.1016/j.amsu.2017.01.019
Three years evaluation of retained foreign bodies after surgery in Iran.
Аннотация
BACKGROUND
Medical errors such as retained foreign bodies (RFB) during surgery are not well studied. To define risk factors associated with this type of error, we performed retrospective study.
METHODS
We reviewed medical records for unintentional foreign object remaining in the body during surgery such as gender, age, surgery ward, and incident reports referred to several forensic medicine administrations as well as adverse effects of retained foreign bodies and methods for detection of them over a 3-years period from January 2008 through May 2011.
RESULTS
Thirty eight patients were involved in the study to have retained foreign bodies (73% sponges and 27% other instruments including 7 (18.42%) cases of other bandages, 2 cases (5.26%) of scissor and 1 case (2.63%) of forceps). The general surgery ward was most commonly involved (47%) followed by the gynecology surgery ward (34%). Men (58%) were more involved with RFB than women (42%).
CONCLUSION
Considering the most frequent type of retained foreign bodies and also more frequent involved surgery wards besides detection methods for RFB, a mixed of preventing protocols such as regular counting of devices, post-operative X-ray with radiopaque markers and exact evaluation of surgery site should be employed to reduce the occurrence of retained foreign bodies and its complications.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.