Teo Yao Neng, Sia Ching-Hui, Tan Benjamin Y Q, Mingxue Jing, Chan Bernard, Sharma Vijay Kumar, Makmur Andrew, Gopinathan Anil, Yang Cunli, Loh Stanley, Ng Sheldon, Ong Shao Jin, Teoh Hock-Luen, Rathakrishnan Rahul, Andersson Tommy, Arnberg Fabian, Gontu Vamsi Krishna, Lee Tsong-Hai, Maus Volker, Meyer Lukas, Bhogal Pervinder, Spooner Oliver, Li Tony Yw, Soh Rodney Yh, Yeo Leonard Ll

МетаанализСистематический обзорСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The use of a combination of balloon guide catheter (BGC), aspiration catheter, and stent retriever in acute ischemic stroke thrombectomy has not been shown to be better than a stent retriever and BGC alone, but this may be due to a lack of power in these studies. We therefore performed a meta-analysis on this subject.

METHODS

A systematic literature search was performed on PubMed, Scopus, Embase/Ovid, and the Cochrane Library from inception to October 20, 2021. Our primary outcomes were the rate of successful final reperfusion (Treatment in Cerebral Ischemia (TICI) 2c-3) and first pass effect (FPE, defined as TICI 2c-3 in a single pass). Secondary outcomes were 3 month functional independence (modified Rankin Scale score of 0-2), mortality, procedural complications, embolic complications, and symptomatic intracranial hemorrhage (SICH). A meta-analysis was performed using RevMan 5,4, and heterogeneity was assessed using the I2 test.

RESULTS

Of 1629 studies identified, five articles with 2091 patients were included. For the primary outcomes, FPE (44.9% vs 45.4%, OR 1.04 (95% CI 0.90 to 1.22), I2=57%) or final successful reperfusion (64.5% vs 68.6%, OR 0.98 (95% CI 0.81% to 1.20%), I2=85%) was similar between the combination technique and stent retriever only groups. However, the combination technique had significantly less rescue treatment (18.8% vs 26.9%; OR 0.70 (95% CI 0.54 to 0.91), I2=0%). This did not translate into significant differences in secondary outcomes in functional outcomes, mortality, emboli, complications, or SICH.

CONCLUSION

There was no significant difference in successful reperfusion and FPE between the combined techniques and the stent retriever and BGC alone groups. Neither was there any difference in functional outcomes, complications, or mortality.

Для цитирования: Teo Yao Neng, Sia Ching-Hui, Tan Benjamin Y Q, Mingxue Jing, Chan Bernard, Sharma Vijay Kumar, Makmur Andrew, Gopinathan Anil, Yang Cunli, Loh Stanley, Ng Sheldon, Ong Shao Jin, Teoh Hock-Luen, Rathakrishnan Rahul, Andersson Tommy, Arnberg Fabian, Gontu Vamsi Krishna, Lee Tsong-Hai, Maus Volker, Meyer Lukas, Bhogal Pervinder, Spooner Oliver, Li Tony Yw, Soh Rodney Yh, Yeo Leonard Ll. Combined balloon guide catheter, aspiration catheter, and stent retriever technique versus balloon guide catheter and stent retriever alone technique: a systematic review and meta-analysis.. Journal of neurointerventional surgery. 2022. DOI: 10.1136/neurintsurg-2021-018406.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.