MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/neurintsurg-2014-011237

Медицинская библиотека · Journal of neurointerventional surgery · 2014

Flow diverter stents for unruptured saccular anterior circulation perforating artery aneurysms: safety, efficacy, and short-term follow-up.

Kühn Anna Luisa, Hou Samuel Y, Perras Mary, Brooks Christopher, Gounis Matthew J, Wakhloo Ajay K, Puri Ajit S

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Anterior circulation perforating artery aneurysms including anterior choroidal artery and lenticulostriate artery aneurysms are rare. Injury to these vessels can lead to severe debilitating symptoms.

OBJECTIVE

To present a new approach to treatment using flow diversion technology.

METHODS

Patients treated with a Pipeline embolization device (PED) for perforator artery aneurysms at our institution between June 2012 and May 2013 were identified and included in our retrospective analysis. We evaluated patient vascular risk factors; family history of aneurysms; aneurysm characteristics; National Institutes of Health Stroke Scale (NIHSS) and modified Rankin Scale (mRS) on admission; and angiography follow-up and patient clinical outcome at discharge, 6 months, and 1 year.

RESULTS

We included four patients with a mean age of 59.8 years. Two patients had a positive family history of aneurysms. Patient vascular risk factors included smoking, dyslipidemia, and hypertension. All patients presented with a NIHSS and mRS of 0 on admission. Aneurysms were located at the anterior choroidal (n=2) or lenticulostriate artery (n=2) and were treated with a single PED. No periprocedural or postprocedural complications occurred. The patients were discharged with no change in NHISS or mRS score. Six-month and 1-year follow-up angiography showed complete aneurysm occlusion. Mild intimal hyperplasia was seen in 2 cases at 6 months, but was resolved at the 1-year follow-up. No re-treatment was necessary. NIHSS and mRS remained 0 at follow-up time points.

CONCLUSIONS

Our preliminary results show that flow diversion technology is an effective and safe therapy for complex, hard-to-treat aneurysms in perforating arteries. Larger studies with long-term follow-up are needed to validate our promising results.

Для цитирования: Kühn Anna Luisa, Hou Samuel Y, Perras Mary, Brooks Christopher, Gounis Matthew J, Wakhloo Ajay K, Puri Ajit S. Flow diverter stents for unruptured saccular anterior circulation perforating artery aneurysms: safety, efficacy, and short-term follow-up.. Journal of neurointerventional surgery. 2014. DOI: 10.1136/neurintsurg-2014-011237.