OBJECTIVES
Our objective was to analyze variations in the optic nerve (ON) course and surrounding structures in an effort to construct an optic nerve injury risk profile before endoscopic intranasal sphenoidal, or endoscopic endonasal transphenoidal, skull-base surgery, and eventually to construct and formulate a common classification by combining the known classes. The authors used computed tomography (CT) toward this end.
METHODS
The authors retrospectively reviewed 200 consecutive CT scans (400 sides) of the paranasal sinuses. The pneumatization of the anterior clinoid process, the relationships of the ONs to the sphenoidal sinuses, and ON dehiscence were evaluated. The authors then created a formula by which risk profiles can be constructed for patients for whom sphenoid or parasellar surgery is planned.
RESULTS
Pneumatization of the anterior clinoid process was evident in 28.25%. Dehiscence of the bony wall of the ON was evident in 9.5%. The ON course lay adjacent to the sphenoidal sinus, causing sinus wall indentation, in 23%. Cumulative optic nerve injury risk scoring showed that, radiologically, surgery on 8.5% and 1.5% of sphenoid sinuses described here carried severe or critical risk of ON injury, respectively.
CONCLUSIONS
Head-and-neck surgeons and neurosurgeons should be aware of variations in ON course. The authors composed an optic nerve injury risk classification category based on the sum of individual weights of each of these classes. Reductions in ON injuries require careful evaluation of potential variant anatomies. Preoperative CT scans must be meticulously reviewed to avoid ON injury.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.