An innovative technique for facial deformity reconstruction following mucormycosis using three-dimensional printing: a case report.

Ahmad Ahmad Fayez

Клинический случайСтатьяПеревод в очереди

Аннотация

INTRODUCTION AND

IMPORTANCE

Extensive destruction of the facial bones caused by mucormycosis poses a significant challenge for surgeons during the reconstruction phase. In this context, three-dimensional (3D) printing plays a pivotal role in the accurate planning and design of patient-specific implants tailored to the patient's deficient bone anatomy.

PRESENTATION OF CASE: A 52-year-old male patient presented with extensive destruction of the maxilla, zygomatic bones, and the floor of the nasal cavity secondary to mucormycosis. The patient was unable to phonate or swallow due to oronasal communication resulting from complete continuity between the oral and nasal cavities.

DISCUSSION: Conventional reconstructive approaches typically require large volumes of autologous bone grafts, prolonged operative time, and multiple surgical stages. Accordingly, reconstruction using 3D printing technology with patient-specific titanium implants was employed.

CONCLUSION

Reconstruction with a 3D-printed, patient-specific titanium implant yielded a satisfactory outcome within a single surgical procedure and a relatively short operative time. Furthermore, precise 3D planning facilitated subsequent dental rehabilitation.

Для цитирования: Ahmad Ahmad Fayez. An innovative technique for facial deformity reconstruction following mucormycosis using three-dimensional printing: a case report.. International journal of surgery case reports. 2026. DOI: 10.1097/rc9.0000000000000682.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.