Effect of Dexmedetomidine on Perception of Paresthesia during Subthalamic Nucleus Deep Brain Stimulation Surgery for Parkinson's Disease.
Аннотация
BACKGROUND
Deep brain stimulation (DBS) has become a well-established treatment for the management of Parkinson's disease (PD). The most common method of lead targeting utilizes microelectrode recording (MER) and intraoperative macrostimulation to confirm accurate placement of the lead. This has been significantly aided by the use of dexmedetomidine (DEX) sedation during the procedure. Despite the frequent use of DEX, it has been theorized that DEX may have some effects on the MER during intraoperative testing. The effect on the perception of sensory thresholds during macrostimulation in the form of paresthesia is still unreported.
OBJECTIVES
To investigate the effect of the sedative DEX on sensory perception thresholds observed in the intraoperative versus postoperative settings for patients undergoing subthalamic nucleus (STN) DBS surgery for PD.
MATERIALS AND
METHODS
Adult patients (n = 8) with a diagnosis of PD underwent placement of DBS leads (n = 14) in the STN. Patients were subjected to intraoperative macrostimulation for capsular and sensory thresholds prior to placement of each DBS lead. These were compared to sensory thresholds observed in the postoperative setting during outpatient programming at three depths on each lead (n = 42).
RESULTS
In most contacts (22/42) (P = 0.19), sensory thresholds for paresthesia perception were either perceived at a higher voltage or absent during intraoperative testing in comparison to those observed in the postoperative setting.
CONCLUSIONS
DEX appears to have measurable (though not statistically significant) effect on the perception of paresthesia observed during intraoperative testing.