m+Medelevator.RU
← Поиск публикаций
Clinical imaging · 2011

Assessment of the cerebellar arteries with multidetector computed tomography angiography benefits from submillimeter slice thickness.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Grieser Christian, Steffen Ingo G, Gartenschläger Sören, Stiepani Heiner, Perez Fernandez Carmen M, Hamm Bernd, Denecke Timm

Аннотация

PURPOSE: To evaluate the accuracy of 64-row-multidetector computed tomography (MDCT) with different slice thickness (0.625 vs. 1.25 mm) in assessing the cerebellar arteries.

MATERIALS AND METHODS: A total of 21 consecutive patients who underwent computed tomography angiography (CTA) of the cervicocranial arteries (64-row MDCT; slice thickness, 0.625 mm) because of suspicion of cerebral ischemia were enrolled retrospectively. The MDCT data set was secondarily reconstructed to a slice thickness of 1.25 mm. The examinations were reviewed by three independent blinded observers. Recorded parameters for reconstructed slice thicknesses of 0.625 compared to 1.25 mm were visualization and edge enhancement (based on a developed phantom reference model) of the cerebellar arteries including anterior and posterior inferior cerebellar arteries and the superior cerebellar artery.

RESULTS: With 0.625-mm slices, significantly more vessel segments were visualized and edge enhancement was superior compared to 1.25-mm slices by the three readers, and a significant difference for the interaction between vessel segments and the slice thickness was found (P<.001). Furthermore, for a slice thickness of 1.25 mm, there was a significant difference in visualization (P=.0042) and edge enhancement (P=.0015) of vessel segments between the three readers, whereas for thinner slices (0.625 mm), no significant differences were found (P=.412, P=.465).

CONCLUSIONS: MDCT with slice thickness of 0.625 mm is superior to 1.25 mm reconstructed slice thickness regarding the visualization of cerebellar arteries, representative for smallest assessable arteries in CTA. This is paralleled by a sharper edge enhancement of the vessel contours resulting from a reduced partial volume effect. Conclusively, cranial CTA protocols should be routinely optimized to generate submillimeter slices for diagnostic purposes and digital storage as additional diagnostic value can be expected.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты