OBJECTIVE

Targeted parathyroidectomy is the gold standard for localized parathyroid disease. A robotic-assisted approach has not been investigated. The aim was to assess the feasibility of a robotic technique that avoids a neck scar.

STUDY

DESIGN

Feasibility study.

SETTING

Tertiary referral center.

SUBJECTS AND

METHODS

Eleven patients with primary hyperparathyroidism were prospectively evaluated. Triple modality concordant localization was a prerequisite. All patients underwent robotic-assisted parathyroidectomy (RAP). Outcome variables assessed were operative time, voice change, biochemical cure, and histopathological confirmation. Patient-reported outcome measures (PROMs) included subjective assessment of pain and scar cosmesis, Voice Handicap Index 2, and EQ-5D quality-of-life assessment. Mean follow-up was 6 months (range, 3-12 months).

RESULTS

The parathyroid adenoma was successfully excised in all cases with negligible blood loss (<5 mL). There was 1 conversion. There was no voice change in any case. Robot docking time plateaued to 10 minutes after 8 cases. Mean exposure and console times (31 and 51 minutes, respectively) were affected by body habitus. The mean visual analog scale for scar cosmesis was 75% on the first postoperative day, improving to 92% at 6 months and 95% at 1 year. Pain scores decreased to 8% at 2 weeks. All 5 EQ-5D quality-of-life parameters significantly improved following surgery.

CONCLUSION

The robotic approach is feasible for performing targeted parathyroidectomy that avoids a neck scar. The clinical efficacy and cost-effectiveness of the robotic approach compared with conventional targeted parathyroidectomy warrant further evaluation to establish if this represents a viable alternative to the existing targeted techniques.

Для цитирования: Tolley Neil, Arora Asit, Palazzo Fausto, Garas George, Dhawan Ranju, Cox Jeremy, Darzi Ara. Robotic-assisted parathyroidectomy: a feasibility study.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2011. DOI: 10.1177/0194599811402152.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.