MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/cddis.2012.38

Медицинская библиотека · Cell death & disease · 2012

Resistance to ABT-737 in activated T lymphocytes: molecular mechanisms and reversibility by inhibition of the calcineurin-NFAT pathway.

Cippà P E, Kraus A K, Lindenmeyer M T, Chen J, Guimezanes A, Bardwell P D, Wekerle T, Wüthrich R P, Fehr T

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Dynamic regulation of the intrinsic apoptosis pathway controls central and peripheral lymphocyte deletion, and may interfere with the pro-apoptotic potency of B-cell lymphoma 2 inhibitors such as ABT-737. By following a T-cell receptor (TCR) transgenic population of alloantigen-specific T cells, we found that sensitivity to ABT-737 radically changed during the course of allo-specific immune responses. Particularly, activated T cells were fully resistant to ABT-737 during the first days after antigen recognition. This phenomenon was caused by a TCR-calcineurin-nuclear factor of activated T cells-dependent upregulation of A1, and was therefore prevented by cyclosporine A (CsA). As a result, exposure to ABT-737 after alloantigen recognition induced selection of alloreactive T cells in vivo, whereas in combination with low-dose CsA, ABT-737 efficiently depleted alloreactive T cells in murine host-versus-graft and graft-versus-host models. Thus, ABT-737 resistance is not a prerogative of neoplastic cells, but it physiologically occurs in T cells after antigen recognition. Reversibility of this process by calcineurin inhibitors opens new pharmacological opportunities to modulate this process in the context of cancer, autoimmunity and transplantation.

Для цитирования: Cippà P E, Kraus A K, Lindenmeyer M T, Chen J, Guimezanes A, Bardwell P D, Wekerle T, Wüthrich R P, Fehr T. Resistance to ABT-737 in activated T lymphocytes: molecular mechanisms and reversibility by inhibition of the calcineurin-NFAT pathway.. Cell death & disease. 2012. DOI: 10.1038/cddis.2012.38.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.