Recanalization of femoropopliteal chronic total occlusions using the ENABLER-P Balloon Catheter System.

Zeller Thomas, Kambara Antonio M, Moreira Samuel M, Atar Eliyahu, Chulsky Alexander, Turgeman Yoav, Sixt Sebastian, Tepe Gunnar, Rastan Aljoscha, Buchbinder Maurice

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the safety and effectiveness of a new system to facilitate intraluminal advancement of conventional guidewires through chronic total occlusions (CTO) of the superficial femoral artery (SFA) and popliteal artery.

METHODS

The ENABLER-P Balloon Catheter System uses a unique balloon-anchoring mechanism and an automated balloon inflation device for steady, controlled advancement of a standard non-hydrophilic guidewire. The system was evaluated in 37 patients (22 men; mean age 67 years (range 41-87) with femoropopliteal CTOs averaging 86 mm in length (range 10-340). The device was used in a variety of occlusions, including heavily calcified, long, and fibrotic lesions. After successful guidewire recanalization facilitated by the system, occluded arterial segments were treated conventionally with balloon angioplasty, atherectomy, and stents as appropriate.

RESULTS

The primary endpoint of successful crossing was achieved in 86% (32/37) of the overall study population. The average activation time for successful crossing was 5.3 minutes (range 0.4-22). Of the 32 cases successfully crossed with the ENABLER-P System, all but 1 was successfully recanalized. One (3%) device-related complication occurred when the wire was advanced into a side branch when treating a 300-mm-long flush ostial SFA occlusion; the resulting perforation was managed with a covered stent without further sequelae.

CONCLUSION

This novel system, which provides enhanced force to a standard guidewire tip for controlled intraluminal advancement, is a promising device for the treatment of peripheral CTOs.

Для цитирования: Zeller Thomas, Kambara Antonio M, Moreira Samuel M, Atar Eliyahu, Chulsky Alexander, Turgeman Yoav, Sixt Sebastian, Tepe Gunnar, Rastan Aljoscha, Buchbinder Maurice. Recanalization of femoropopliteal chronic total occlusions using the ENABLER-P Balloon Catheter System.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2012. DOI: 10.1583/11-3664.1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.