MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/sla.0b013e3181bd906b

Медицинская библиотека · Annals of surgery · 2009

Virtual neck exploration: a new method for localizing abnormal parathyroid glands.

Prommegger Rupert, Wimmer Gerd, Profanter Christoph, Sauper Tonja, Sieb Michael, Kovacs Peter, Bale Reto, Putzer Daniel, Gabriel Michael, Margreiter Raimund

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND DATA: Computed tomography (CT) together with 99mTc-sestamibi single photon emission computed tomography (MIBI-SPECT) image fusion (CT-MIBI-SPECT image fusion) allows virtual exploration of the neck. The aim of this study was to evaluate whether CT-MIBI-SPECT image fusion is superior to MIBI-SPECT and CT in detecting abnormal parathyroid glands in patients with primary hyperparathyroidism.

METHODS

CT-MIBI-SPECT image fusion for preoperative localization was performed in 116 patients with primary hyperparathyroidism (pHPT). Both investigations were performed with reproducible fixation of the patient on a vacuum mattress. At a special work station the neck was virtually explored by viewing the CT images in all 3 dimensions. The MIBI-SPECT images were superimposed on underlying CT images. Only patients with single-gland disease were evaluated (pHPT: 112, persistent pHPT: 1, recurrent pHPT: 1, persistent secondary hyperparathyroidism: 1, tertiary HPT after kidney transplantation: 1). CT-MIBI-SPECT image fusion results were compared with those obtained with CT alone and MIBI-SPECT alone. The predicted positions were correlated with the intraoperative findings.

RESULTS

CT-MIBI-SPECT image fusion was able to predict the exact position of the abnormal gland in 102 (88%) of the 116 patients, whereas CT alone showed in 75 (65%) patients and MIBI-SPECT alone in 64 (55%) patients the exact position of the abnormal gland. Sixty-two patients underwent minimally invasive surgery, namely in 21 patients with a unilaterally focused approach and in 33 patients with a bilateral approach (27 of these underwent simultaneous thyroid resection). Sensitivity for CT-MIBI-SPECT image fusion was 88%, for CT alone 70%, and for MIBI-SPECT alone 59%. Specificity for CT-MIBI-SPECT image fusion was 99%, for MIBI-SPECT alone 95%, for CT alone 94%. Overall accuracy for CT-MIBI-SPECT image fusion was 97%, for CT alone 89%, for MIBI-SPECT 87%.

CONCLUSIONS

This study provides evidence that CT-MIBI-SPECT image fusion is superior to CT or MIBI-SPECT alone for preoperative localization of enlarged parathyroid glands in patients with single-gland primary hyperparathyroidism.

Для цитирования: Prommegger Rupert, Wimmer Gerd, Profanter Christoph, Sauper Tonja, Sieb Michael, Kovacs Peter, Bale Reto, Putzer Daniel, Gabriel Michael, Margreiter Raimund. Virtual neck exploration: a new method for localizing abnormal parathyroid glands.. Annals of surgery. 2009. DOI: 10.1097/sla.0b013e3181bd906b.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.