MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/14670100.2023.2172828

Медицинская библиотека · Cochlear implants international · 2023

The experience of auditory implant recipients undergoing magnetic resonance imaging: Factors associated with pain.

Smith Matthew E, Moualed Daniel J, Freeman Simon R, Stapleton Emma J, Anup Raji, Kurian Jincy, Jarvis Nicola, Thomas Owen M, Lloyd Simon K W

Наблюдательное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Many patients with cochlear implants (CI) and auditory brainstem implants (ABI) require magnetic resonance imaging (MRI) following implantation. This study explores the patient experience of MRI, identifying factors associated with pain, and the effect of interventions designed to enhance comfort and safety.

METHODS

A prospective observational case series from a tertiary referral unit. Tight head bandaging ± local anaesthetic injection (devices with non-MRI-compatible magnets) or observation alone (implants with MRI-compatible magnets) were employed for 1.5 T MRI of consecutive adult patients with CI or ABI without magnet removal. Pain was recorded via visual analogue scale (1 = no pain, 5 = extreme pain) at three time points; (1) baseline, (2) head bandage applied (3) during scanning. Patient age, device type, body area imaged and total scan time were recorded as variables, alongside adverse events.

RESULTS

Data were collected for 227 MRI scans (34 patients with ABI, 32 with CI). In patients managed with bandaging, pain score after bandaging but prior to scanning (median 2.2) did not differ from pain during scanning (2.1), but both were significantly higher than baseline (1.4, both P ≤ 0.001). Scanning areas other than the head/cervical spine was associated with higher pain scores (P = 0.036). Pain during MRI differed between different manufacturers implants (P ≤ 0.001). Adverse events occurred in 8/227 scans (3.5%), none occurring with devices containing an MRI-compatible magnet.

CONCLUSION

MRI scanning with auditory implant magnets in situ is safe and well tolerated by patients.

Для цитирования: Smith Matthew E, Moualed Daniel J, Freeman Simon R, Stapleton Emma J, Anup Raji, Kurian Jincy, Jarvis Nicola, Thomas Owen M, Lloyd Simon K W. The experience of auditory implant recipients undergoing magnetic resonance imaging: Factors associated with pain.. Cochlear implants international. 2023. DOI: 10.1080/14670100.2023.2172828.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.