MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00106-026-01725-5

Медицинская библиотека · HNO · 2026

[Electrocochleography with an extratympanic tympanic membrane electrode : Age-dependent reference values for vertigo diagnostics].

Gawliczek Tom, Morrison Miranda Claire, Keller Katharine, Korda Athanasia, Weder Stefan, Caversaccio Marco D, Mantokoudis Georgios

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

BACKGROUND

Electrocochleography (ECochG) records electrical potentials of the inner ear and is used, among other applications, in the diagnostic work-up of Ménière's disease. For extratympanic recordings, age-dependent reference values are currently lacking, which limits clinical interpretation.

OBJECTIVE

This study aims to establish age-stratified reference ranges for the summating potential (SP)/action potential (AP) amplitude and area ratios for noninvasive diagnostics in patients with suspected endolymphatic hydrops.

MATERIALS AND

METHODS

A total of 47 ears from 26 normal-hearing volunteers aged 20-70 years were examined using an extratympanic tympanic membrane electrode. The SP and AP potentials were recorded in a standardized manner. Amplitude and area ratios were calculated and analyzed with respect to age and laterality.

RESULTS

The reference ranges (P5-P95) were 0.13-0.46 for the SP/AP amplitude ratio and 0.72-1.72 for the SP/AP area ratio. No significant side differences were observed. A slight age-related increase in both parameters was detected, without a clinically relevant impact.

CONCLUSION

Extratympanic ECochG enables a minimally invasive and reliable diagnostic approach with age-stratified reference values. It represents a practical adjunct to imaging in Ménière's disease and allows a more differentiated assessment of pathological inner ear function.

Для цитирования: Gawliczek Tom, Morrison Miranda Claire, Keller Katharine, Korda Athanasia, Weder Stefan, Caversaccio Marco D, Mantokoudis Georgios. [Electrocochleography with an extratympanic tympanic membrane electrode : Age-dependent reference values for vertigo diagnostics].. HNO. 2026. DOI: 10.1007/s00106-026-01725-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.