MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000331934

Медицинская библиотека · Cerebrovascular diseases (Basel, Switzerland) · 2011

A new image-based stroke registry containing quantitative magnetic resonance imaging data.

Kim Dong-Eog, Park Kyoung-Jong, Schellingerhout Dawid, Jeong Sang-Wuk, Ji Myung-Goo, Choi Won Jun, Tak Yoon-Oh, Kwan Geon-Hwan, Koh Eun Ah, Noh Sang-Mi, Jang Hyung Yeol, Kim Tae-Yun, Jeong Ji-Won, Lee Jae Sung, Choi Heung-Kook

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Conventional stroke registries contain alphanumeric text-based data on the clinical status of stroke patients, but this format captures imaging data in a very limited form. There is a need for a new type of stroke registry to capture both text- and image-based data.

METHODS AND

RESULTS

We designed a next-generation stroke registry containing quantitative magnetic resonance imaging (MRI) data, 'DUIH_SRegI', developed a supporting software package, 'Image_QNA', and performed experiments to assess the feasibility and utility of the system. Image_QNA enabled the mapping of stroke-related lesions on MR onto a standard brain template and the storage of this extracted imaging data in a visual database. Interuser and intrauser variability of the lesion mapping procedure was low. We compared the results from the semi automatic lesion registration using Image_QNA with automatic lesion registration using SPM5 (Statistical Parametric Mapping version 5), a well-regarded standard neuroscience software package, in terms of lesion location, size and shape, and found Image_QNA to be superior. We assessed the clinical usefulness of an image-based registry by studying 47 consecutive patients with first-ever lacunar infarcts in the corona radiata. We used the enriched dataset comprised of both image-based and alphanumeric databases to show that diffusion MR lesions overlapped in a more posterolateral brain location for patients with high NIH Stroke Scale scores (≥4) than for patients with low scores (≤3). In April 2009, we launched the first prospective image-based acute (≤1 week) stroke registry at our institution. The registered data include high signal intensity ischemic lesions on diffusion, T(2)-weighted, or fluid attenuation inversion recovery MRIs, and low signal intensity hemorrhagic lesions on gradient-echo MRIs. An interim analysis at 6 months showed that the time requirement for the lesion registration (183 consecutive patients, 3,226 MR slices with visible stroke-related lesions) was acceptable at about 1 h of labor per patient by a trained assistant with physician oversight.

CONCLUSIONS

We have developed a novel image-based stroke registry, with database functions that allow the formulation and testing of intuitive, image-based hypotheses in a manner not easily achievable with conventional alphanumeric stroke registries.

Для цитирования: Kim Dong-Eog, Park Kyoung-Jong, Schellingerhout Dawid, Jeong Sang-Wuk, Ji Myung-Goo, Choi Won Jun, Tak Yoon-Oh, Kwan Geon-Hwan, Koh Eun Ah, Noh Sang-Mi, Jang Hyung Yeol, Kim Tae-Yun, Jeong Ji-Won, Lee Jae Sung, Choi Heung-Kook. A new image-based stroke registry containing quantitative magnetic resonance imaging data.. Cerebrovascular diseases (Basel, Switzerland). 2011. DOI: 10.1159/000331934.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.