DOI 10.1016/j.ultrasmedbio.2021.09.020

Медицинская библиотека · Ultrasound in medicine & biology · 2021

Diagnostic Performance of 2-D Shear Wave Elastography on the Evaluation of Hepatic Fibrosis with Emphasis on Impact of the Different Region-of-Interest Methods.

Kim Eun Mi, Park Ji-Won, Lee Sang Min, Kim Min-Jeong, Ha Hong Il, Kim Sung-Eun, Kim Eun Soo, Kim Young Chul, Lee Kwanseop

СтатьяПеревод пока не подготовлен

Аннотация

The purpose of this study was to evaluate the impact of the different region-of-interest (ROI) methods of 2-D shear wave elastography (2-D SWE) on hepatic fibrosis diagnosis. In this retrospective study, 83 patients who underwent 2-D SWE with three ROI methods (a circle ROI, a box ROI and multiple ROIs in an elastogram) and transient elastography (TE) were included. Liver stiffness (LS) was measured five times with each ROI method. These LS values were compared, and their correlation with those obtained from TE was evaluated. The LS values obtained using the three different ROI methods differed statistically (p < 0.001). However, the LS values obtained using each ROI method of 2-D SWE were highly correlated with those obtained using TE (r > 0.7, p < 0.001). All three ROI methods of 2-D SWE had high areas under the receiver operating characteristic curve in diagnosing significant fibrosis and cirrhosis (0.841, 0.820 and 0.840, respectively; 0.962, 0.946 and 0.945, respectively). There were no significant differences in area under the receiver operating characteristic curve among the ROI methods of 2-D SWE. Regardless of the ROI method, 2-D SWE had high performance in diagnosing hepatic fibrosis.

Для цитирования: Kim Eun Mi, Park Ji-Won, Lee Sang Min, Kim Min-Jeong, Ha Hong Il, Kim Sung-Eun, Kim Eun Soo, Kim Young Chul, Lee Kwanseop. Diagnostic Performance of 2-D Shear Wave Elastography on the Evaluation of Hepatic Fibrosis with Emphasis on Impact of the Different Region-of-Interest Methods.. Ultrasound in medicine & biology. 2021. DOI: 10.1016/j.ultrasmedbio.2021.09.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.