Initial experience with the 5 × 300-mm Proteus embolic capture angioplasty balloon in the treatment of peripheral vascular disease.

Zeller Thomas, Schmidt Andrej, Rastan Aljoscha, Noory Elias, Sixt Sebastian, Scheinert Dierk

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To describe the use of the 5 × 300-mm Proteus embolic capture angioplasty (ECA) balloon catheter to reduce embolic burden in complex TASC II (TransAtlantic Inter-Society Consensus) C and D femoropopliteal interventions.

METHODS

A non-randomized safety and feasibility study was conducted at 2 centers enrolling 15 subjects (9 women; mean age 72.5 ± 9.5 years, range 53-85) suffering from Rutherford-Becker category 2 to 4 occlusive disease. Of the 20 lesions in 15 limbs, 16 were TASC II D and 4 were TASC II C. Average baseline stenosis was 95%± 12%; 16 lesions were totally occluded. Half of the lesions were de novo, 5 were restenotic, and 5 were in-stent stenoses. Average lesion length was 284 ± 50 mm. In addition to using the ECA device, 18 of the target lesions were treated with stents and 4 with rotational thrombectomy devices. Distal angiography was performed before and after use of the ECA device to locate any periprocedural embolic events.

RESULTS

Procedural success was achieved in 100% lesions. The ECA balloon was used for predilation in 11 lesions and for postdilation in 9. No distal embolization or flow-limiting vessel dissections were observed despite the complex nature of the cases. Three non-device-related complications were reported (pseudoaneurysm, myocardial infarction, acute renal failure) and resolved without sequelae within 30 days. Analysis of the particles recovered from 5 ECA balloons demonstrated a mean 257 ± 185 particles, with a mean major axial dimension of 0.54 ± 0.04 mm (range 0.11-7.54). There were a mean 7.67 ± 6.03 particles >2 mm in diameter, and all samples contained 1 to 3 particles >4 mm in diameter.

CONCLUSION

In this small series, the 5 × 300-mm ECA embolic capture balloon catheter was an effective tool for avoiding embolic events in long peripheral lesions, with a good safety profile. The device might be considered as part of routine clinical practice for complex TASC II C/D femoropopliteal lesions.

Для цитирования: Zeller Thomas, Schmidt Andrej, Rastan Aljoscha, Noory Elias, Sixt Sebastian, Scheinert Dierk. Initial experience with the 5 × 300-mm Proteus embolic capture angioplasty balloon in the treatment of peripheral vascular disease.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2012. DOI: 10.1583/jevt-12-3960mr.1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.