MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13089-021-00207-9

Медицинская библиотека · The ultrasound journal · 2021

Bedside lung ultrasonography by emergency department residents as an aid for identifying heart failure in patients with acute dyspnea after a 2-h training course.

Msolli Mohamed Amine, Sekma Adel, Marzouk Maryem Ben, Chaabane Wael, Bel Haj Ali Khaoula, Boukadida Lotfi, Bzeouich Nasri, Gannoun Imen, Trabelssi Imen, Laaouiti Kamel, Grissa Mohamed Habib, Beltaief Kaouthar, Dridi Zohra, Belguith Asma, Methamem Mehdi, Bouida Wahid, Boukef Riadh, Boubaker Hamdi, Nouira Semir, GREAT Network

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Ultrasonographic B-lines have recently emerged as a bedside imaging tool for the differential diagnosis of acute dyspnea in the Emergency Department (ED). However, despite its simplicity, LUS has not fully penetrated emergency department. This study aimed to assess the accuracy and reproducibility of ultrasonographic B-lines performed by emergency medicine (EM) residents for the diagnosis of congestive heart failure (CHF) in patients admitted to ED for acute dyspnea.

PATIENTS AND

METHODS

This is a cross-sectional prospective study conducted between January 2016 and October 2017 including patients aged over 18 years admitted to ED for acute dyspnea. At admission, two consecutive bedside LUS study were performed by a pair of EM residents who received a 2-h course for recognition of sonographic B-lines to determine independently B-lines score and B-profile pattern. All participating sonographers were blinded to patients' clinical data. B-lines score ≥ 15 or a B-profile pattern was considered as suggestive of CHF. The final leading diagnosis was assessed by two expert sonographers, who were blinded to the residents' interpretations, based on clinical findings, chest X-ray, brain natriuretic peptide, cardiac and lung ultrasound testing. Accuracy and agreement of B-lines score and B-profile pattern were calculated.

RESULTS

We included 700 patients with a mean age of 68 ± 12.6 years and a sex ratio (M/F) of 1.43. The diagnosis of CHF was recorded in 371 patients (53%). The diagnostic performance of B-lines score at a cut-off 15 and B-profile pattern was, respectively, 88% and 82.5% for sensitivity, 75% and 84% for specificity, 80% and 85% for positive predictive value, 84% and 81% for negative predictive value. The area under receiver operating characteristic curve was 0.86 [0.83-0.89] and 0.83 [0.80-0.86], respectively, for B-lines score and B-profile pattern. There was an excellent agreement between residents for the diagnosis of CHF using both scores (kappa = 0.81 and 0.85, respectively, for ordinal scale B-lines score and B-profile pattern).

CONCLUSION

Lung ultrasound B-lines assessment has a good accuracy and an excellent reproducibility in the diagnosis of CHF in the hand of EM residents following a short training program. Trial registration Name of the registry: clinicaltrials.gov; Trial registration number: NCT03717779; Date of registration: October 24, 2018 'Retrospectively registered'; URL of trial registry record: clinicaltrials.gov.

Для цитирования: Msolli Mohamed Amine, Sekma Adel, Marzouk Maryem Ben, Chaabane Wael, Bel Haj Ali Khaoula, Boukadida Lotfi, Bzeouich Nasri, Gannoun Imen, Trabelssi Imen, Laaouiti Kamel, Grissa Mohamed Habib, Beltaief Kaouthar, Dridi Zohra, Belguith Asma, Methamem Mehdi, Bouida Wahid, Boukef Riadh, Boubaker Hamdi, Nouira Semir, GREAT Network. Bedside lung ultrasonography by emergency department residents as an aid for identifying heart failure in patients with acute dyspnea after a 2-h training course.. The ultrasound journal. 2021. DOI: 10.1186/s13089-021-00207-9.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.