Interpretable morphological features for efficient single-lead automatic ventricular ectopy detection.

Malik John, Loring Zak, Piccini Jonathan P, Wu Hau-Tieng

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

We designed an automatic, computationally efficient, and interpretable algorithm for detecting ventricular ectopic beats in long-term, single-lead electrocardiogram recordings.

METHODS

We built five simple, interpretable, and computationally efficient features from each cardiac cycle, including a novel morphological feature which described the distance to the median beat in the recording. After an unsupervised subject-specific normalization procedure, we trained an ensemble binary classifier using the AdaBoost algorithm

RESULTS

After our classifier was trained on subset DS1 of the Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) Arrhythmia database, our classifier obtained an F1 score of 94.35% on subset DS2 of the same database. The same classifier achieved F1 scores of 92.06% on the St. Petersburg Institute of Cardiological Technics (INCART) 12-lead Arrhythmia database and 91.40% on the MIT-BIH Long-term database. A phenotype-specific analysis of model performance was afforded by the annotations included in the St. Petersburg INCART Arrhythmia database

CONCLUSION

The five features this novel algorithm employed allowed our ventricular ectopy detector to obtain high precision on previously unseen subjects and databases SIGNIFICANCE: Our ventricular ectopy detector will be used to study the relationship between premature ventricular contractions and adverse patient outcomes such as congestive heart failure and death.

Для цитирования: Malik John, Loring Zak, Piccini Jonathan P, Wu Hau-Tieng. Interpretable morphological features for efficient single-lead automatic ventricular ectopy detection.. Journal of electrocardiology. 2020. DOI: 10.1016/j.jelectrocard.2020.11.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.