DOI 10.1016/j.clinph.2011.12.014
Conductive neuromagnetic fields in the lumbar spinal canal.
Аннотация
OBJECTIVE
To measure neuromagnetic evoked fields in the lumbar spinal canal.
METHODS
Using a newly developed superconducting quantum interference device (SQUID) fluxmeter, neuromagnetic fields of 5 healthy male volunteers were measured at the surface of the lower back after stimulation of the tibial nerves at the ankles. For validation, we inserted a catheter-type electrode percutaneously in the lumbar epidural space in 2 of the subjects and measured cauda equina action potentials after tibial nerve stimulation.
RESULTS
Neuromagnetic fields propagating from the intervertebral foramina into the spinal canal were measured, and the latencies of the magnetic fields corresponded largely with those of the cauda equina action potentials.
CONCLUSIONS
We successfully measured ascending neuromagnetic fields originating at the nerve root and the cauda equina with high spatial resolution. Future studies will determine whether neuromagnetic field measurement of the lumbar spine can be a useful diagnostic method for the identification of the disordered site in spinal nerves.
SIGNIFICANCE: We successfully measured neuromagnetic fields in the lumbar spinal canal, which have previously been difficult to verify. Future studies will determine whether neuromagnetic field measurement of the lumbar spine can be a useful diagnostic method for identifying disorders of spinal nerves.