MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5334/tohm.886

Медицинская библиотека · Tremor and other hyperkinetic movements (New York, N.Y.) · 2024

Validation of a New Patient-Reported Outcome Measure of the Functional Impact of Essential Tremor on Activities of Daily Living.

Shih Ludy C, Stevenson Michael T, Bellows Steven, Fasano Alfonso, Kuo Sheng-Han, Lyons Kelly E, Moore Henry, Shill Holly A, Wagle Shukla Aparna, Singer Carlos, Elble Rodger J

СтатьяВалидационное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The Essential Tremor Rating Assessment Scale (TETRAS) is a popular scale for essential tremor (ET), but its activities of daily living (ADL) and performance (P) subscales are based on a structured interview and physical exam. No patient-reported outcome (PRO) scale for ET has been developed according to US regulatory guidelines.

OBJECTIVE

Develop and validate a TETRAS PRO subscale.

METHODS

Fourteen items, rated 0-4, were derived from TETRAS ADL and structured cognitive interviews of 18 ET patients. Convergent validity analyses of TETRAS PRO versus TETRAS ADL, TETRAS-P, and the Quality of Life in Essential Tremor Questionnaire (QUEST) were computed for 67 adults with ET or ET plus. Test-retest reliability was computed at intervals of 1 and 30 days. The influence of mood (Hospital Anxiety and Depression Scale, HADS) and coping behaviors (Essen Coping Questionnaire, ECQ) was examined with multiple linear regression.

RESULTS

TETRAS PRO was strongly correlated (r > 0.7) with TETRAS ADL, TETRAS-P, and QUEST and exhibited good to excellent reliability (Cronbach alpha 95%CI = 0.853-0.926; 30-day test-retest intraclass correlation 95%CI = 0.814-0.921). The 30-day estimate of minimum detectable change (MDC) was 6.6 (95%CI 5.2-8.0). TETRAS-P (rsemipartial = 0.607), HADS depression (rsemipartial = 0.384), and the coping strategy of information seeking and exchange of experiences (rsemipartial = 0.176) contributed statistically to TETRAS PRO in a multiple linear regression (R2 = 0.67).

CONCLUSIONS

TETRAS PRO is a valid and reliable scale that is influenced strongly by tremor severity, moderately by mood (depression), and minimally by coping skills. The MDC for TETRAS PRO is probably sufficient to detect clinically important change.

Для цитирования: Shih Ludy C, Stevenson Michael T, Bellows Steven, Fasano Alfonso, Kuo Sheng-Han, Lyons Kelly E, Moore Henry, Shill Holly A, Wagle Shukla Aparna, Singer Carlos, Elble Rodger J. Validation of a New Patient-Reported Outcome Measure of the Functional Impact of Essential Tremor on Activities of Daily Living.. Tremor and other hyperkinetic movements (New York, N.Y.). 2024. DOI: 10.5334/tohm.886.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.