m+Medelevator.RU
← Поиск публикаций
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2025

Self-Expanding Aortic Endoprosthesis for Conduit Preparation Prior to Transcatheter Pulmonary Valve Replacement.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Krebushevski Kaitlyn, Cabalka Allison K, Pollak Peter M, Yu Liwei, Anderson Jason H

Аннотация

BACKGROUND: Preparation of the right ventricular outflow tract (RVOT) using covered stent placement is a common preparatory step for transcatheter pulmonary valve replacement (TPVR) to reduce the risk of disruption associated with dilating calcified RVOT conduits.

AIM: We present a novel method employing a self-expanding covered aortic endoprosthesis and discuss its advantages as an alternative strategy.

METHODS: Patients with congenital heart disease undergoing RVOT conduit preparation with the GORE TAG Thoracic Branch Endoprosthesis Extender (W.L. Gore & Associates, Newark, DE) followed by TPVR, were prospectively enrolled in a dedicated database. To date, 14 patients have been included. Data on demographics, diagnoses, procedural details, hemodynamic parameters, and outcomes were analyzed.

RESULTS: Fourteen patients (median age: 35 years [range: 18-79]; 57% female) successfully underwent endograft placement immediately before TPVR. Treated conduits included pulmonary homografts (n = 8), surgical bioprostheses (n = 2), Hancock conduit (n = 1), Contegra conduit (n = 1), native RVOT (n = 1), and Melody valve within a surgical bioprosthesis (n = 1). Most patients presented with mixed stenosis and regurgitation (n = 9), with the remaining having stenosis (n = 4) or regurgitation (n = 1). Valves implanted post-preparation included the Sapien S3 valve (Edwards Lifesciences, Irvine, CA) (n = 10) and the Melody valve (Medtronic, Minneapolis, MN) (n = 5). Significant reductions in RVOT systolic gradient were observed (median 34 mmHg pre-procedure to 3 mmHg post-procedure), along with marked conduit expansion (median diameter 13 mm pre-procedure to 25.5 mm post-procedure). No complications were reported.

CONCLUSIONS: This study highlights the feasibility of a self-expanding aortic endoprosthesis for RVOT preparation before TPVR. Further comparative study is warranted. Procedural success was achieved in all cases.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты