Backscattering Mueller matrix polarimetry estimates microscale anisotropy and orientation in complex brain tissue structure.

Carlson Rhea, Comrie Courtney, Bonaventura Justina, Morara Kellys, Daigle Noelle, Hutchinson Elizabeth, Sawyer Travis W

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Diffusion magnetic resonance imaging (dMRI) quantitatively estimates brain microstructure, diffusion tractography being one clinically utilized framework. To advance such dMRI approaches, direct quantitative comparisons between microscale anisotropy and orientation are imperative. Complete backscattering Mueller matrix polarized light imaging (PLI) enables the imaging of thin and thick tissue specimens to acquire numerous optical metrics not possible through conventional transmission PLI methods. By comparing complete PLI to dMRI within the ferret optic chiasm (OC), we may investigate the potential of this PLI technique as a dMRI validation tool and gain insight into the microstructural and orientational sensitivity of this imaging method in different tissue thicknesses.

APPROACH: Post-mortem ferret brain tissue samples (whole brain, n = 1 and OC, n = 3 ) were imaged with both dMRI and complete backscattering Mueller matrix PLI. The specimens were sectioned and then reimaged with PLI. Region of interest and correlation analyses were performed on scalar metrics and orientation vectors of both dMRI and PLI in the coherent optic nerve and crossing chiasm.

RESULTS

Optical retardance and dMRI fractional anisotropy showed similar trends between metric values and were strongly correlated, indicating a bias to macroscale architecture in retardance. Thick tissue displays comparable orientation between the diattenuation angle and dMRI fiber orientation distribution glyphs that are not evident in the retardance angle.

CONCLUSIONS

We demonstrate that backscattering Mueller matrix PLI shows potential as a tool for microstructural dMRI validation in thick tissue specimens. Performing complete polarimetry can provide directional characterization and potentially microscale anisotropy information not available by conventional PLI alone.

Для цитирования: Carlson Rhea, Comrie Courtney, Bonaventura Justina, Morara Kellys, Daigle Noelle, Hutchinson Elizabeth, Sawyer Travis W. Backscattering Mueller matrix polarimetry estimates microscale anisotropy and orientation in complex brain tissue structure.. Journal of medical imaging (Bellingham, Wash.). 2024. DOI: 10.1117/1.jmi.12.1.016001.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.