Optimal mitral annular and subvalvular shape change created by the Coapsys device to treat functional mitral regurgitation.

Fukamachi Kiyotaka, Inoue Masahiro, Popović Zoran, Ootaki Yoshio, Kopcak Michael W, Dessoffy Raymond, Thomas James D, McCarthy Patrick M

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

We have reported that the Myocor Coapsys (Myocor, Inc, Maple Grove, MN) device treated functional mitral regurgitation (MR) by reducing mitral annular dimension and repositioning papillary muscles. This study was conducted to evaluate the optimal Coapsys device sizing level. The Coapsys device was implanted in seven dogs after induction of MR by rapid ventricular pacing. The device consists of anterior and posterior pads connected by a subvalvular cord. The device was tightened in 5% increments of the left ventricular epicardial to epicardial dimension up to 40%. Hemodynamic and echocardiographic measurements were repeated at each tightening level. The Coapsys significantly reduced or eliminated functional MR, and the reduction was maximized at the 30% tightening level or lower in all cases. Although the left ventricular end diastolic volume decreased significantly, forward stroke volume was maintained until the 35% tightening level. The forward ejection fraction significantly increased from 33 +/- 24% at baseline to 62 +/- 42% at 40% tightening level. Mean aortic pressure decreased slightly but significantly. The Coapsys device can be applied over a broad range of tightening levels with significant reduction in MR without negative physiologic impact. This feature makes the device usable [corrected] in a variety of clinical settings.

Для цитирования: Fukamachi Kiyotaka, Inoue Masahiro, Popović Zoran, Ootaki Yoshio, Kopcak Michael W, Dessoffy Raymond, Thomas James D, McCarthy Patrick M. Optimal mitral annular and subvalvular shape change created by the Coapsys device to treat functional mitral regurgitation.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2005. DOI: 10.1097/01.mat.0000150511.87747.a1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.