MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2004.06.120

Медицинская библиотека · The Annals of thoracic surgery · 2005

Video and robotic-assisted minimally invasive mitral valve surgery: a comparison of the Port-Access and transthoracic clamp techniques.

Reichenspurner Hermann, Detter Christian, Deuse Tobias, Boehm Dieter H, Treede Hendrik, Reichart Bruno

Клиническое исследованиеСравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

In order to assess different surgical techniques for video-assisted minimally invasive mitral valve surgery, a retrospective study was undertaken comparing the Port-Access system (Cardiovations, Ethicon Inc, Somerville, NJ) and the transthoracic clamp technique.

METHODS

In 120 patients mitral valve surgery was performed through a small right minithoracotomy using either the Port-Access endovascular cardiopulmonary bypass system (Port-Access, n = 60) or the transthoracic clamp technique (MICRO, n = 60). Mean patient age was 61.5 +/- 10.5 years (81 patients with isolated mitral valve insufficiency, 39 patients with combined mitral valve disease).

RESULTS

Eighty-one (67.5%) patients underwent mitral valve repair and 39 (32.5%) patients had valve replacement. Mean time of surgery was 4.5 +/- 3.5 and 4.1 +/- 3.2 hours (p = 0.07), aortic cross-clamp time 89 +/- 69 and 78 +/- 65 minutes (p = 0.08), mean intensive care unit stay 1.5 +/- 2.1 and 1.6 +/- 2.5 days (p = ns), and hospital stay 9.0 +/- 10.5 and 9.2 +/- 9.7 days (p = ns) in the Port-Access and MICRO groups, respectively. In the Port-Access group, there were 6 reexplorations for bleeding, one perforation of the right ventricle with the endopulmonary vent, and 2 reconstructions of the femoral artery necessary after femoral cannulation, compared to one reexploration for bleeding in the MICRO group. There was only one minor paravalvular leak after replacement and 2 cases of residual greater than or equal to grade II mitral valve regurgitation after mitral valve repair in the Port-Access group, necessitating reoperation. In both groups, there was no mortality, no cerebrovascular accident, no aortic dissection, and no conversion to sternotomy.

CONCLUSIONS

Minimally invasive mitral valve surgery has become a standard approach for isolated mitral valve operations at our institution. The MICRO technique tends to shorten the time of surgery and aortic cross-clamping and reduces perioperative costs by simplifying the operative procedure.

Для цитирования: Reichenspurner Hermann, Detter Christian, Deuse Tobias, Boehm Dieter H, Treede Hendrik, Reichart Bruno. Video and robotic-assisted minimally invasive mitral valve surgery: a comparison of the Port-Access and transthoracic clamp techniques.. The Annals of thoracic surgery. 2005. DOI: 10.1016/j.athoracsur.2004.06.120.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.