MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The Journal of heart valve disease · 2004

Evaluation of stentless kangaroo aortic valves in the mitral position of juvenile sheep.

Hodge Andrew J, Neethling William M L, Glancy Ross

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND AIM OF THE STUDY: The performance and longevity of bioprosthetic heart valves are limited by tissue calcification and degeneration after implantation. Experimental valve replacement in large animal models forms an important component of the preclinical evaluation of these bioprosthetic heart valves. The study aim was to assess the feasibility of a mitral model for stentless valves and to evaluate the calcification behavior of stentless glutaraldehyde-preserved kangaroo heart valves in the mitral position of a sheep model.

METHODS

Medtronic Freestyle (n = 10) and kangaroo (n = 11) stentless aortic valves were implanted in the mitral position of juvenile sheep and retrieved after a maximum of 200 days. Retrieved stentless valves were examined for morphological changes and calcification of the valve tissue, using radiological screening, Von Kossa's staining and atomic absorption spectrophotometry.

RESULTS

Four sheep (40.0%) with Medtronic Freestyle and 10 sheep (90.9%) with kangaroo valves could be weaned from bypass and mechanical ventilation. Two animals (20.0%) with Medtronic Freestyle and six animals (54.5%) with kangaroo prostheses survived more than 30 days postoperatively. No significant difference (p >0.05) was seen between the calcification potential of Medtronic Freestyle valve leaflets (3.21 +/- 1.67 microg/mg) after 93 days and kangaroo valve leaflets (2.39 +/- 0.80 microg/mg) after 200 days.

CONCLUSION

The present results suggest that implantation of a stentless valve in the mitral position of sheep is possible, but technically difficult. The calcification potential of kangaroo valve tissue is comparable to that of Freestyle valve tissue in the mitral position of sheep.

Для цитирования: Hodge Andrew J, Neethling William M L, Glancy Ross. Evaluation of stentless kangaroo aortic valves in the mitral position of juvenile sheep.. The Journal of heart valve disease. 2004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.