MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.sleep.2011.12.010

Медицинская библиотека · Sleep medicine · 2012

Impact of continuous positive airway pressure treatment on right ventricle performance in patients with obstructive sleep apnoea, assessed by three-dimensional echocardiography.

Oliveira Wercules, Poyares Dalva, Cintra Fatima, Vieira Marcelo L C, Fischer Claudio H, Moises Valdir, Tufik Sergio, Carvalho Antonio, Campos Orlando

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Obstructive sleep apnoea (OSA) is a predictor of right ventricle (RV) impairment. However, there is scant information on the effect of OSA treatment on RV performance. We sought to evaluate the impact of OSA treatment with a continuous positive airway pressure (CPAP) device on RV volume and function, as well as on variables related to pulmonary vascular haemodynamics.

METHODS

Fifty-six OSA patients and 50 controls were studied. All individuals underwent three-dimensional echocardiogram (3DE) to estimate RV volumes, function, pulmonary vascular resistance, and tricuspid regurgitation velocity. A total of 30 patients with apnoea-hypopnoea index greater than 20 were randomly selected to receive placebo (n=15) or effective CPAP (n=15) for 24 weeks. They underwent 3DE examination on three different occasions: at baseline, after 12 weeks, and after 24 weeks of CPAP or placebo.

RESULTS

Higher pulmonary vascular resistance (2.1 Wood's ± 0.5 vs. 1.8 Wood's ± 0.4), larger end-diastolic RV volume index (52.2 mL/m(2) ± 7.3 vs. 49.9 mL/m(2) ± 6.0), larger end-systolic RV volume index (18.7 mL/m(2) ± 4.3 vs. 15.4 mL/m(2) ± 3.6), and lower RV ejection fraction (64.3% ± 6.8 vs. 68.4% ± 5.9) were observed in the OSA group compared to non-OSA controls (P<0.05, all). In the effective CPAP group we observed the following changes from the baseline to the 24-week echo evaluation: (A) reduction in pulmonary vascular resistance (2.2 Wood's ± 0.3 to 1.8 Wood's ± 0.3); (B) reduction in the RV end-systolic volume index (20.3 mL/m(2) ± 4.5 to 16 mL/m(2) ± 2.1); and (C) increase in RV ejection fraction (63.0% ± 7.2 to 70.8% ± 0.9) (P<0.05 for all).

CONCLUSION

Twenty-four-week treatment with CPAP improved RV performance but did not change RV structural variables.

Для цитирования: Oliveira Wercules, Poyares Dalva, Cintra Fatima, Vieira Marcelo L C, Fischer Claudio H, Moises Valdir, Tufik Sergio, Carvalho Antonio, Campos Orlando. Impact of continuous positive airway pressure treatment on right ventricle performance in patients with obstructive sleep apnoea, assessed by three-dimensional echocardiography.. Sleep medicine. 2012. DOI: 10.1016/j.sleep.2011.12.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.