DOI 10.1007/s00784-019-03155-w
Effect of photobiomodulation therapies on the root resorption associated with orthodontic forces: a pilot study using micro computed tomography.
Аннотация
OBJECTIVES
The aim of this study is to investigate the effect of photobiomodulation therapies on root resorption compared with the placebo group.
MATERIALS AND
METHODS
Thirty patients who were admitted to the Gaziantep University Faculty of Dentistry Orthodontics Department for treatment, with an indication of upper right first premolar tooth extraction were included. Before the individuals' orthodontic treatment, 0.022 slot MBT brackets and tubes were placed on the maxillary first premolar and molar. A 150-g buccal tipping force was applied to the first premolar. Cantilever spring with 0.017 × 0.025 Beta Titanium wire was used for force application. Individuals were then randomly divided into three groups. For the first group, laser application was performed with an 810-nm GaAlAs laser device at 0, 3, 7, 14, 21, and 28 days to 8 J/cm2. For the second group, an LED application according to the manufacturer's instructions with an 850-nm wavelength and 20 mW/cm2 output power for 10 min per day during the experiment. For the third group, a placebo therapy was completed whereby a laser device that did not make active pulses was used. At the end of 4 weeks, the amount of root surface resorption was compared using micro-CT imaging after the extraction of the teeth.
RESULTS
No significant difference was found between the groups in terms of regional and total crater volumes. It was observed that photobiomodulation therapies were not different from the control group in terms of forming root resorption.
CONCLUSIONS
It is seen that laser and LED photobiomodulation therapies used for accelerate orthodontic tooth movement do not differ from the control group in terms of forming root resorption.
CLINICAL RELEVANCE: According to the results of this pilot study on this subject, which needs to be clarified with new findings in the future, LED and laser applications may not increase the risk for root resorption.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.