MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcv.2021.104905

Медицинская библиотека · Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology · 2021

RT-PCR based SARS-CoV-2 variant screening assays require careful quality control.

Camp Jeremy V, Buchta Christoph, Jovanovic Jovana, Puchhammer-Stöckl Elisabeth, Benka Bernhard, Griesmacher Andrea, Aberle Stephan W, Goerzer Irene

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Distinctive genotypes of SARS-CoV-2 have emerged that are or may be associated with increased transmission, pathogenicity, and/or antibody escape. In many countries, clinical and diagnostic laboratories are under mandate to identify and report these so-called variants of concern (VOC).

OBJECTIVES

We used an external quality assessment scheme to determine the scope, accuracy, and reliability of laboratories using various molecular diagnostic assays to identify current VOC (03 March 2021).

STUDY

DESIGN

Participant laboratories were sent the same five patient-derived samples and were asked to provide their variant detection methods, variant detection results and interpretation of results.

RESULTS

Twenty-five laboratories reported a range of RT-qPCR-based assays to identify specific variations in the SARS-CoV-2 spike protein that are characteristic of three VOC lineages. Laboratories that detected VOC-associated nucleotide mutations at four specific sites had the highest ratio of correct classification. Low template copy number and additional variation in target regions resulted in loss of confidence and accuracy in sample classification.

CONCLUSIONS

Melting-curve-based assays to identify genomic variants are less time-consuming and require less bioinformatic analysis compared to partial or whole genome sequencing. However, our results suggest that correct classification of a given genotype/lineage (e.g., a VOC) relies on the ability to detect more than one variant site, adequate template in the sample (i.e., relatively high viral load/copy number) and results may be unclear in certain samples with additional genetic variations. These initial results suggest that some diagnostic laboratories may require additional training to interpret and report complex genetic information about a dynamic emerging virus.

Для цитирования: Camp Jeremy V, Buchta Christoph, Jovanovic Jovana, Puchhammer-Stöckl Elisabeth, Benka Bernhard, Griesmacher Andrea, Aberle Stephan W, Goerzer Irene. RT-PCR based SARS-CoV-2 variant screening assays require careful quality control.. Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology. 2021. DOI: 10.1016/j.jcv.2021.104905.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.