DOI 10.1111/ina.12899

Медицинская библиотека · Indoor air · 2021

Affordable measures to monitor and alarm nosocomial SARS-CoV-2 infection due to poor ventilation.

Lu Yiran, Li Yifan, Zhou Hao, Lin Jinlan, Zheng Zhuozhao, Xu Huji, Lin Borong, Lin Minggui, Liu Li

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Since the coronavirus disease 2019 (COVID-19) outbreak, the nosocomial infection rate worldwide has been reported high. It is urgent to figure out an affordable way to monitor and alarm nosocomial infection. Carbon dioxide (CO2 ) concentration can reflect the ventilation performance and crowdedness, so CO2 sensors were placed in Beijing Tsinghua Changgung Hospital's fever clinic and emergency department where the nosocomial infection risk was high. Patients' medical records were extracted to figure out their timelines and whereabouts. Based on these, site-specific CO2 concentration thresholds were calculated by the dilution equation and sites' risk ratios were determined to evaluate ventilation performance. CO2 concentration successfully revealed that the expiratory tracer was poorly diluted in the mechanically ventilated inner spaces, compared to naturally ventilated outer spaces, among all of the monitoring sites that COVID-19 patients visited. Sufficient ventilation, personal protection, and disinfection measures led to no nosocomial infection in this hospital. The actual outdoor airflow rate per person (Qc ) during the COVID-19 patients' presence was estimated for reference using equilibrium analysis. During the stay of single COVID-19 patient wearing a mask, the minimum Qc value was 15-18 L/(s·person). When the patient was given throat swab sampling, the minimum Qc value was 21 L/(s·person). The Qc value reached 36-42 L/(s·person) thanks to window-inducted natural ventilation, when two COVID-19 patients wearing masks shared the same space with other patients or healthcare workers. The CO2 concentration monitoring system proved to be effective in assessing nosocomial infection risk by reflecting real-time dilution of patients' exhalation.

Для цитирования: Lu Yiran, Li Yifan, Zhou Hao, Lin Jinlan, Zheng Zhuozhao, Xu Huji, Lin Borong, Lin Minggui, Liu Li. Affordable measures to monitor and alarm nosocomial SARS-CoV-2 infection due to poor ventilation.. Indoor air. 2021. DOI: 10.1111/ina.12899.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.