MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21037/cdt.2020.01.10

Медицинская библиотека · Cardiovascular diagnosis and therapy · 2020

Intra- and inter-observer reproducibility of multilayer cardiac magnetic resonance feature tracking derived longitudinal and circumferential strain.

Ananthapadmanabhan Saikrishna, Deng Echo, Femia Giuseppe, Tang Simon, Koh Eng-Siew, Schuster Andreas, Puranik Raj, Gupta Pankaj, Nguyen Tuan, Dimitri Hany, Otton James

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Multilayer strain measurement with cardiac magnetic resonance feature tracking (CMR-FT) allows independent assessment of endocardial and epicardial strain. This novel method of layer-specific quantification of myocardial deformation parameters provides greater insight into contractility compared to whole-layer strain analysis. The clinical utility of this technique is promising. The aim of this study is to investigate the intra- and inter- observer reproducibility of CMR-FT derived multilayer global longitudinal strain (GLS) and global circumferential strain (GCS) parameters in the setting of normal cardiac function, cardiac pathology, and differing MRI field strengths.

METHODS

We studied 4 groups of 20 subjects, comprising of patients with dilated cardiomyopathy, ischemic heart disease, and patients without cardiac pathology at both 1.5 and 3 T. Quantitative measures of whole-layer and multi-layer longitudinal and circumferential strain were calculated using CMR-FT software.

RESULTS

Intraclass correlation coefficients (ICC) for intraobserver reproducibility of endocardial, epicardial, and whole-layer measurements of GLS were 0.979, 0.980, and 0.978 respectively, and those for GCS were 0.986, 0.977, and 0.985. ICCs for inter-observer reproducibility of endocardial, epicardial, and whole-layer measurements of GLS were 0.976, 0.970, and 0.976, and those for GCS were 0.982, 0.969, and 0.981. Bland Altman analysis showed minimal bias and acceptable limits of agreement (LOA) within each patient subgroup and the overall cohort. Circumferential and longitudinal strain parameters were equally reproducible in the overall cohort.

CONCLUSIONS

CMR-FT derived multilayer measurements of longitudinal and circumferential strain demonstrate high intra- and inter- observer reproducibility, with suitability for use in clinical practice.

Для цитирования: Ananthapadmanabhan Saikrishna, Deng Echo, Femia Giuseppe, Tang Simon, Koh Eng-Siew, Schuster Andreas, Puranik Raj, Gupta Pankaj, Nguyen Tuan, Dimitri Hany, Otton James. Intra- and inter-observer reproducibility of multilayer cardiac magnetic resonance feature tracking derived longitudinal and circumferential strain.. Cardiovascular diagnosis and therapy. 2020. DOI: 10.21037/cdt.2020.01.10.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.